Suppr超能文献

通过流动注射分析结合荧光检测法测定人血清氨基脲敏感胺氧化酶活性,该方法是在酶促生成的苯甲醛与1,2-二氨基蒽醌进行在线衍生化之后进行的。

Determination of human serum semicarbazide-sensitive amine oxidase activity via flow injection analysis with fluorescence detection after online derivatization of the enzymatically produced benzaldehyde with 1,2-diaminoanthraquinone.

作者信息

El-Maghrabey Mahmoud H, Kishikawa Naoya, Ohyama Kaname, Imazato Takahiro, Ueki Yukitaka, Kuroda Naotaka

机构信息

Course of Pharmaceutical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan; Analytical Chemistry Department, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt.

Course of Pharmaceutical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan.

出版信息

Anal Chim Acta. 2015 Jun 30;881:139-47. doi: 10.1016/j.aca.2015.04.006. Epub 2015 Apr 4.

Abstract

A fast, simple, and sensitive flow injection analysis method was developed for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human serum. Benzaldehyde, generated by the action of SSAO after incubation of serum with benzylamine, was derivatized with a novel aromatic aldehyde-specific reagent (1,2-diaminoanthraquinone) and the fluorescent product was measured by fluorescence detection at excitation and emission wavelengths of 390 and 570nm, respectively. Serum SSAO activity was defined as benzaldehyde (nmol) formed per milliliter serum per hour. The method was linear over SSAO activity of 0.2-150.0nmolmL(-1)h(-1) with a detection limit of 0.06nmolmL(-1)h(-1). The %RSD of intra-day and inter-day precision did not exceed 9.4% and the accuracy ranged from -6.5 to -0.6%. The method was applied for the determination of the serum SSAO activity in healthy controls (C, n=24) and diabetes mellitus patients (DM, n=18). It was demonstrated that the activity (mean±SE) of SSAO in diabetics sera was significantly higher than that in healthy subjects' ones (DM; 73.3±1.8nmolmL(-1)h(-1)vs C; 58.9±2.2nmolmL(-1)h(-1), P<0.01).

摘要

开发了一种快速、简单且灵敏的流动注射分析方法,用于测定人血清中对氨基脲敏感的胺氧化酶(SSAO)活性。血清与苄胺孵育后,由SSAO作用产生的苯甲醛用一种新型的芳香醛特异性试剂(1,2-二氨基蒽醌)进行衍生化,并通过荧光检测分别在激发波长390nm和发射波长570nm下测定荧光产物。血清SSAO活性定义为每毫升血清每小时形成的苯甲醛(纳摩尔)量。该方法在SSAO活性为0.2 - 150.0nmol·mL⁻¹·h⁻¹范围内呈线性,检测限为0.06nmol·mL⁻¹·h⁻¹。日内和日间精密度的相对标准偏差(%RSD)不超过9.4%,准确度范围为 - 6.5%至 - 0.6%。该方法应用于健康对照组(C组,n = 24)和糖尿病患者(DM组,n = 18)血清SSAO活性的测定。结果表明糖尿病患者血清中SSAO的活性(均值±标准误)显著高于健康受试者(DM组;73.3±1.8nmol·mL⁻¹·h⁻¹ vs C组;58.9±2.2nmol·mL⁻¹·h⁻¹,P<0.01)。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验