A fast, simple, and sensitive flow injection analysis method was developed for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human serum. Benzaldehyde, generated by the action of SSAO after incubation of serum with benzylamine, was derivatized with a novel aromatic aldehyde-specific reagent (1,2-diaminoanthraquinone) and the fluorescent product was measured by fluorescence detection at excitation and emission wavelengths of 390 and 570nm, respectively. Serum SSAO activity was defined as benzaldehyde (nmol) formed per milliliter serum per hour. The method was linear over SSAO activity of 0.2-150.0nmolmL(-1)h(-1) with a detection limit of 0.06nmolmL(-1)h(-1). The %RSD of intra-day and inter-day precision did not exceed 9.4% and the accuracy ranged from -6.5 to -0.6%. The method was applied for the determination of the serum SSAO activity in healthy controls (C, n=24) and diabetes mellitus patients (DM, n=18). It was demonstrated that the activity (mean±SE) of SSAO in diabetics sera was significantly higher than that in healthy subjects' ones (DM; 73.3±1.8nmolmL(-1)h(-1)vs C; 58.9±2.2nmolmL(-1)h(-1), P<0.01).
开发了一种快速、简单且灵敏的流动注射分析方法,用于测定人血清中对氨基脲敏感的胺氧化酶(SSAO)活性。血清与苄胺孵育后,由SSAO作用产生的苯甲醛用一种新型的芳香醛特异性试剂(1,2-二氨基蒽醌)进行衍生化,并通过荧光检测分别在激发波长390nm和发射波长570nm下测定荧光产物。血清SSAO活性定义为每毫升血清每小时形成的苯甲醛(纳摩尔)量。该方法在SSAO活性为0.2 - 150.0nmol·mL⁻¹·h⁻¹范围内呈线性,检测限为0.06nmol·mL⁻¹·h⁻¹。日内和日间精密度的相对标准偏差(%RSD)不超过9.4%,准确度范围为 - 6.5%至 - 0.6%。该方法应用于健康对照组(C组,n = 24)和糖尿病患者(DM组,n = 18)血清SSAO活性的测定。结果表明糖尿病患者血清中SSAO的活性(均值±标准误)显著高于健康受试者(DM组;73.3±1.8nmol·mL⁻¹·h⁻¹ vs C组;58.9±2.2nmol·mL⁻¹·h⁻¹,P<0.01)。