Suppr超能文献

[隔音窗对北京某临街住宅建筑室内噪声水平的预防效果]

[Preventive effects of sound insulation windows on the indoor noise levels in a street residential building in Beijing].

作者信息

Guo Bin, Huang Jing, Guo Xin-biao

机构信息

Department of Occupational and Environmental Health Sciences, Peking University School of Public Health, Beijing 100191, China.

出版信息

Beijing Da Xue Xue Bao Yi Xue Ban. 2015 Jun 18;47(3):450-4.

Abstract

OBJECTIVE

To evaluate the preventive effects of sound insulation windows on traffic noise.

METHODS

Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared.

RESULTS

The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (P<0.05), which complied with the indoor noise level standards in our country. The closed or open states of the sound insulation windows had significant influence on the indoor noise levels (P<0.05). Compared with the open state of the sound insulation window, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads.

CONCLUSION

Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.

摘要

目的

评估隔音窗对交通噪声的预防效果。

方法

使用声级计测量安装有隔音窗(北四环路边和校园边的住宅房间)关闭时室内的噪声水平,并与同时测量的室外噪声水平进行比较。此外,还比较了隔音窗关闭和打开时房间内噪声水平的差异。

结果

北四环的室外平均噪声水平高于70dB(A),超过了我国《声环境质量标准》(GB 3096-2008)规定的限值。然而,关闭隔音窗时,室内噪声水平显著降低至35dB(A)以下(P<0.05),符合我国室内噪声水平标准。隔音窗的关闭或打开状态对室内噪声水平有显著影响(P<0.05)。与隔音窗打开状态相比,关闭隔音窗时,北四环路边和校园边住宅房间的室内噪声水平分别降低了18.8dB(A)和8.3dB(A)。结果表明,安装隔音窗对临街住宅建筑尤其是面向主要交通道路的房间有显著的降噪效果。

结论

安装隔音窗对临街住宅建筑的室内噪声有显著的预防作用。