Suppr超能文献

细胞膜通透性对磁共振扩散测量的时间依赖性影响

Time-Dependent Influence of Cell Membrane Permeability on MR Diffusion Measurements.

作者信息

Li Hua, Jiang Xiaoyu, Xie Jingping, McIntyre J Oliver, Gore John C, Xu Junzhong

机构信息

Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.

Department of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee, USA.

出版信息

Magn Reson Med. 2016 May;75(5):1927-34. doi: 10.1002/mrm.25724. Epub 2015 Jun 11.

Abstract

PURPOSE

To investigate the influence of cell membrane permeability on diffusion measurements over a broad range of diffusion times.

METHODS

Human myelogenous leukemia K562 cells were cultured and treated with saponin to selectively alter cell membrane permeability, resulting in a broad physiologically relevant range of 0.011-0.044 μm/ms. Apparent diffusion coefficient (ADC) values were acquired with the effective diffusion time (Δeff ) ranging from 0.42 to 3000 ms. Cosine-modulated oscillating gradient spin echo (OGSE) measurements were performed to achieve short Δeff from 0.42 to 5 ms, while stimulated echo acquisitions were used to achieve long Δeff from 11 to 2999 ms. Computer simulations were also performed to support the experimental results.

RESULTS

Both computer simulations and experiments in vitro showed that the influence of membrane permeability on diffusion MR measurements is highly dependent on the choice of diffusion time, and it is negligible only when the diffusion time is at least one order of magnitude smaller than the intracellular exchange lifetime.

CONCLUSION

The influence of cell membrane permeability on the measured ADCs is negligible in OGSE measurements at moderately high frequencies. By contrast, cell membrane permeability has a significant influence on ADC and quantitative diffusion measurements at low frequencies such as those sampled using conventional pulsed gradient methods.

摘要

目的

研究细胞膜通透性在广泛的扩散时间范围内对扩散测量的影响。

方法

培养人髓性白血病K562细胞,并用皂苷处理以选择性改变细胞膜通透性,从而产生0.011 - 0.044μm/ms的广泛生理相关范围。在有效扩散时间(Δeff)范围为0.42至3000 ms的情况下获取表观扩散系数(ADC)值。进行余弦调制振荡梯度自旋回波(OGSE)测量以实现0.42至5 ms的短Δeff,同时使用受激回波采集来实现11至2999 ms的长Δeff。还进行了计算机模拟以支持实验结果。

结果

计算机模拟和体外实验均表明,膜通透性对扩散磁共振测量的影响高度依赖于扩散时间的选择,并且仅当扩散时间比细胞内交换寿命至少小一个数量级时才可以忽略不计。

结论

在中等高频的OGSE测量中,细胞膜通透性对测量的ADC的影响可以忽略不计。相比之下,细胞膜通透性对低频下的ADC和定量扩散测量有显著影响,例如使用传统脉冲梯度方法采样的那些测量。

相似文献

引用本文的文献

本文引用的文献

2
Revealing mesoscopic structural universality with diffusion.用扩散揭示介观结构的普遍性。
Proc Natl Acad Sci U S A. 2014 Apr 8;111(14):5088-93. doi: 10.1073/pnas.1316944111. Epub 2014 Mar 24.
4
Noninvasive quantification of solid tumor microstructure using VERDICT MRI.使用 VERDICT MRI 无创定量实体瘤微结构。
Cancer Res. 2014 Apr 1;74(7):1902-12. doi: 10.1158/0008-5472.CAN-13-2511. Epub 2014 Feb 3.
7
Human aquaporins: regulators of transcellular water flow.人类水通道蛋白:跨细胞水流的调节因子。
Biochim Biophys Acta. 2014 May;1840(5):1492-506. doi: 10.1016/j.bbagen.2013.09.033. Epub 2013 Sep 30.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验