Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration.

作者信息

Sadiq Mohammad A, Rashid Aymen, Channa Roomasa, Hatef Elham, Do Diana V, Nguyen Quan Dong, Sepah Yasir J

机构信息

Ocular Imaging Research and Reading Center (OIRRC), Stanley M Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, 68198, USA.

出版信息

F1000Res. 2013 May 23;2:131. doi: 10.12688/f1000research.2-131.v2. eCollection 2013.

Abstract

PURPOSE

To evaluate the reproducibility and reliability of optical coherence tomography scans obtained using the time domain (TD-OCT) Stratus (TM) OCT, and the Spectral Domain (SD-OCT) Spectralis (TM) and Cirrus (TM) OCT devices before and after manual correction in eyes with either Neovascular (NV-AMD) or Non-Neovascular (NNV-AMD) age-related macular degeneration.

DESIGN

Prospective observational study.

SETTING

University-based retina practice.

PATIENTS

Thirty-six patients (50 eyes) with NV-AMD or NNV-AMD.

PROCEDURE

OCT scans were taken simultaneously using one TD-OCT and two SD-OCT devices.

MAIN OUTCOME MEASURES

Macular thickness measurements were assessed before and after correction of the algorithm by constructing Bland-Altman plots for agreement and calculating intraclass correlation coefficients (ICCs) and coefficients of repeatability (COR) to evaluate intraclass repeatability.

RESULTS

Spectralis had the highest number of images needing manual correction.  All machines had high ICCs, with Spectralis having the highest.  Also, Bland-Altman plots indicated that there was low agreement between Cirrus™ and Stratus™, Spectralis™ and Stratus™, while there was good agreement between the Cirrus™ and Spectralis™.  The CORs were lowest for Spectralis (TM) and similar and higher for Cirrus (TM) and Stratus (TM).  Agreement, CORs, and ICCs generally improved after manual correction, but only minimally.

CONCLUSION

Agreement is low between devices, except between both SD-OCT machines.  Manual correction tends to improve results.

摘要

目的

评估在患有新生血管性(NV-AMD)或非新生血管性(NNV-AMD)年龄相关性黄斑变性的眼中,使用时域(TD-OCT)Stratus(TM)OCT、光谱域(SD-OCT)Spectralis(TM)和Cirrus(TM)OCT设备获得的光学相干断层扫描在手动校正前后的可重复性和可靠性。

设计

前瞻性观察性研究。

设置

基于大学的视网膜诊所。

患者

36例患有NV-AMD或NNV-AMD的患者(50只眼)。

程序

使用一台TD-OCT和两台SD-OCT设备同时进行OCT扫描。

主要观察指标

通过构建Bland-Altman图评估一致性,并计算组内相关系数(ICC)和重复性系数(COR)以评估组内重复性,从而在算法校正前后评估黄斑厚度测量值。

结果

Spectralis需要手动校正的图像数量最多。所有机器的ICC都很高,其中Spectralis最高。此外,Bland-Altman图表明,Cirrus™和Stratus™、Spectralis™和Stratus™之间的一致性较低,而Cirrus™和Spectralis™之间的一致性良好。Spectralis(TM)的COR最低,Cirrus(TM)和Stratus(TM)的COR相似且更高。手动校正后,一致性、COR和ICC总体上有所改善,但改善程度很小。

结论

除两台SD-OCT机器之间外,各设备之间的一致性较低。手动校正往往会改善结果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6cb3/4457116/49141bb491bc/f1000research-2-6502-g0000.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验