关节镜下修复肩袖撕裂后使用连续超声评估肩袖肌腱的术后外观

Assessment of the Postoperative Appearance of the Rotator Cuff Tendon Using Serial Sonography After Arthroscopic Repair of a Rotator Cuff Tear.

作者信息

Yoo Hye Jin, Choi Ja-Young, Hong Sung Hwan, Kang Yusuhn, Park Jina, Kim Sae Hoon, Kang Heung Sik

机构信息

Departments of Radiology (H.J.Y., J.-Y.C., S.H.H., Y.K., J.P.) and Orthopedic Surgery (S.H.K.), Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea; and Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea (H.S.K.).

出版信息

J Ultrasound Med. 2015 Jul;34(7):1183-90. doi: 10.7863/ultra.34.7.1183.

Abstract

OBJECTIVES

The purpose of this study was to evaluate serial changes in sonographic findings of a rotator cuff tendon after rotator cuff repair.

METHODS

Sixty-five arthroscopically repaired rotator cuff tears (43 full-thickness tears and 22 partial-thickness tears) were retrospectively included in this study. Serial sonographic examinations were performed at 5 weeks, 3 months, and 6 months after surgery. The sonographic findings of the repaired tendon were assessed for a recurrent tear, tendon thickness, morphologic tendon characteristics, vascularity, and bursitis at each time point.

RESULTS

Four recurrent tears occurred within 3 months of surgery. The postoperative tendon thickness decreased from 5 weeks to 6 months after surgery (P = .001). There were significant changes in the morphologic tendon characteristics, including the echo texture, fibrillar pattern, and surface irregularity of the repaired tendon, from 5 weeks to 6 months after surgery (P < .001). Additionally, subacromial-subdeltoid bursitis and the vascularity of the repaired tendon decreased postoperatively over time.

CONCLUSIONS

Serial sonography after arthroscopic rotator cuff repair was useful for monitoring the postoperative changes in a repaired tendon. The morphologic appearance of the repaired tendon and peritendinous soft tissue changes improved over time and nearly normalized within 6 months of surgery.

摘要

目的

本研究的目的是评估肩袖修复术后肩袖肌腱超声检查结果的系列变化。

方法

本研究回顾性纳入了65例经关节镜修复的肩袖撕裂(43例全层撕裂和22例部分层撕裂)。在术后5周、3个月和6个月进行系列超声检查。在每个时间点评估修复肌腱的超声检查结果,包括复发性撕裂、肌腱厚度、肌腱形态特征、血管分布和滑囊炎。

结果

术后3个月内发生4例复发性撕裂。术后肌腱厚度从术后5周降至6个月(P = .001)。术后5周至6个月,修复肌腱的形态特征发生了显著变化,包括回声纹理、纤维模式和表面不规则性(P < .001)。此外,术后肩峰下-三角肌下滑囊炎和修复肌腱的血管分布随时间减少。

结论

关节镜下肩袖修复术后的系列超声检查有助于监测修复肌腱的术后变化。修复肌腱的形态外观和肌腱周围软组织变化随时间改善,在术后6个月内几乎恢复正常。