Suppr超能文献

基于Scheimpflug摄影系统的健康眼睛虹膜角膜角测量的会话内重复性

Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes.

作者信息

Ruiz-Belda Clara, Piñero David P, Ruiz-Fortes Pedro, Soto-Negro Roberto, Moya Myriam, Pérez-Cambrodí Rafael J, Artola Alberto

机构信息

Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, C/Padre Arrupe, 20, 1st floor, 03016, Alicante, Spain.

Foundation for Visual Quality (FUNCAVIS), Alicante, Spain.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2016 Jan;254(1):169-75. doi: 10.1007/s00417-015-3105-0. Epub 2015 Jul 15.

Abstract

PURPOSE

The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode.

METHODS

A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the Costruzione Strumenti Oftalmici [CSO] Sirius system. Three consecutive measurements of nasal and temporal angles at 0°, ±10°, ±20°, and ±30° meridians were obtained in order to assess the intra-session repeatability of iridocorneal angle measurements provided by the device using the glaucoma analysis mode. Within-subject standard deviation (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) values were calculated.

RESULTS

The mean Sw was 1.07 ± 1.09°, 1.22 ± 1.53°, 0.66 ± 0.51°, 0.86 ± 0.57°, 0.68 ± 0.65°, 0.84 ± 0.68°, and 0.91 ± 0.70° at the temporal 30°, 20°, 10°, 0°, -10°, -20°, and -30° positions, respectively. Mean Sw was 3.13 ± 3.15°, 3.43 ± 3.63°, 2.75 ± 2.29°, 2.19 ± 1.55°, 1.90 ± 1.49°, 2.14 ± 1.74°, and 2.24 ± 2.06° at the temporal -30°, -20°, -10°, 0°, 10°, 20°, and 30° positions, respectively. Mean CV ranged from 1.36 ± 1.05 % (nasal 0° position) to 10.92 ± 13.95 % (nasal -20° position). ICC values ranged from 0.778 to 0.972.

CONCLUSIONS

The glaucoma analysis mode of the Sirius system provides consistent measurements of the iridocorneal angle at different meridians in healthy eyes, with slightly less consistency for nasal measurements. It may be considered a clinically useful non-invasive technique for the detection of potentially occludable angles.

摘要

目的

本研究旨在使用Sirius基于Scheimpflug摄影的系统青光眼分析模式,评估健康眼睛鼻侧和颞侧不同子午线处虹膜角膜角测量的会话内重复性。

方法

本研究共纳入43例年龄在36至79岁之间的患者的43只眼睛。所有眼睛均接受了全面的眼科检查,包括使用Costruzione Strumenti Oftalmici [CSO] Sirius系统进行完整的眼前节分析。在0°、±10°、±20°和±30°子午线处连续进行三次鼻侧和颞侧角度测量,以评估该设备在青光眼分析模式下提供的虹膜角膜角测量的会话内重复性。计算受试者内标准差(Sw)、变异系数(CV)和组内相关系数(ICC)值。

结果

在颞侧30°、20°、10°、0°、-10°、-20°和-30°位置,平均Sw分别为1.07±1.09°、1.22±1.53°、0.66±0.51°、0.86±0.57°、0.68±0.65°、0.84±0.68°和0.91±0.70°。在颞侧-30°、-20°、-10°、0°、10°、20°和30°位置,平均Sw分别为3.13±3.15°、3.43±3.63°、2.75±2.29°、2.19±1.55°、1.90±1.49°、2.14±1.74°和2.24±2.06°。平均CV范围从1.36±1.05%(鼻侧0°位置)到10.92±13.95%(鼻侧-20°位置)。ICC值范围从0.778到0.972。

结论

Sirius系统的青光眼分析模式在健康眼睛的不同子午线处提供了一致的虹膜角膜角测量,鼻侧测量的一致性略低。它可被认为是一种临床上有用的非侵入性技术,用于检测潜在可闭角。