Akilapa Oluwasegun, Gaffey Andy
Kings College Hospital, Department of Orthopaedics and Traumatology, London, United Kingdom.
Birmingham Children's Hospital, Department of Orthopaedics and Traumatology, United Kingdom.
Acta Orthop Traumatol Turc. 2015;49(4):410-5. doi: 10.3944/AOTT.2015.14.0206.
OBJECTIVE: Several clinical studies have reported that the use of hydroxyapatite- (HA) coated pins enhance external fixation. Although these studies have demonstrated higher extraction torques and lower rates of pin loosening with HA coating, there is little evidence to suggest that these biomechanical advantages translate to a lower rate of pin replacement prior to healing. The research question posed was "Is there sufficient evidence to prove that hydroxyapatite coating lowers the rate of pin replacement for external fixation?" METHODS: An electronic search of Medline (Ovid, 1946 - December Week 4 2011), Embase (Ovid, 1980-2011 Week 52), and the Cochrane Central Register of Controlled Trials (Issue 4 of 4, October 2011) was conducted to identify all randomized and quasi-randomized controlled trials which compared HA-coated pins with non-coated pins for external fixation, with particular emphasis on the premature replacement of pins as a consequence of loosening. RESULTS: The combined search strategies retrieved 72 citations. Four randomized controlled trials (101 patients, 327 HA-coated vs. 354 uncoated pins) were included in this review. None of the studies demonstrated a clear benefit between pin types with respect to premature replacement of pins prior to healing. CONCLUSION: This review did not find sufficient evidence to validate the preferential use of HA-coated pins over standard pins as a means of avoiding premature replacement of pins used for external fixation. The use of uncoated pins is justifiable, especially within the context of limited financial resources.
目的:多项临床研究报告称,使用羟基磷灰石(HA)涂层钢针可增强外固定效果。尽管这些研究表明,HA涂层能带来更高的拔出扭矩,并降低钢针松动率,但几乎没有证据表明这些生物力学优势能转化为愈合前更低的钢针更换率。所提出的研究问题是:“是否有足够的证据证明羟基磷灰石涂层能降低外固定钢针的更换率?” 方法:对Medline(Ovid,1946年至2011年第49周)、Embase(Ovid,1980年至2011年第52周)和Cochrane对照试验中心注册库(2011年10月第4期第4卷)进行电子检索,以确定所有比较HA涂层钢针和未涂层钢针用于外固定的随机和半随机对照试验,特别关注因松动导致的钢针过早更换情况。 结果:联合检索策略共检索到72篇文献。本综述纳入了四项随机对照试验(101例患者,327根HA涂层钢针与354根未涂层钢针)。没有一项研究表明在愈合前钢针过早更换方面,不同类型钢针之间存在明显优势。 结论:本综述未发现足够证据证实,相较于标准钢针,优先使用HA涂层钢针可避免外固定钢针过早更换。使用未涂层钢针是合理的,尤其是在资金有限的情况下。
Expert Rev Med Devices. 2005-7
J Biomed Mater Res B Appl Biomater. 2008-8