*Department of Ophthalmology, University of California San Francisco School of Medicine, San Francisco, CA †Wake Forest University School of Medicine, Winston-Salem, NC ‡Case Western Reserve University School of Medicine, Cleveland, OH §Department of Ophthalmology, Juntendo University School of Medicine, Tokyo, Japan.
J Glaucoma. 2016 Jul;25(7):565-70. doi: 10.1097/IJG.0000000000000311.
To investigate the association between ultrasound energy, expressed as cumulative dissipated energy (CDE), and changes in intraocular pressure (IOP) after uncomplicated cataract surgery by phacoemulsification.
In this prospective study, nonglaucomatous subjects underwent cataract surgery by phacoemulsification. IOP was compared by clustered linear regression at 4 separate time-points: preoperative, 1 day, 1 month, and 3 months after cataract surgery. Changes in the IOP were evaluated as a function of CDE using univariate and multivariate clustered linear regression models, which adjusted for sex, ethnicity, age, axial length, spherical equivalent, mean preoperative Shaffer gonioscopy grade of all 4 quadrants, cataract grade, preoperative IOP, central corneal thickness, and use of both eyes in the same subject.
One hundred sixty-one eyes (89 Asian, 49 white, 12 African, and 11 Hispanic) from 116 nonglaucomatous subjects were analyzed. The 161 eyes included 81 right and 80 left eyes. The 89 Asian eyes included 46 Chinese, 35 Filipino, and 8 Vietnamese. Preoperative IOP was 14.9±3.2 mm Hg. Postoperative IOP significantly increased to 16.0±4.9 mm Hg at 1 day (P=0.037) and decreased to 12.4±3.1 and 12.3±3.0 mm Hg at 1 and 3 months, respectively (both P<0.0001). IOP changes at 1 day, 1 month, and 3 months did not demonstrate significant associations with CDE measurements in either univariate or multivariate clustered linear regression analyses (all P>0.05).
The amount of ultrasound energy delivered to the eye during phacoemulsification, expressed as CDE, was not associated with postoperative changes in IOP.
通过超声乳化白内障吸除术,研究以累积耗散能量(CDE)表示的超声能量与单纯性白内障手术后眼压(IOP)变化之间的关联。
在这项前瞻性研究中,非青光眼患者接受了超声乳化白内障吸除术。在4个不同时间点通过聚类线性回归比较眼压:术前、白内障手术后1天、1个月和3个月。使用单变量和多变量聚类线性回归模型,将眼压变化评估为CDE的函数,该模型对性别、种族、年龄、眼轴长度、等效球镜度、所有4个象限术前平均Shaffer前房角镜分级、白内障分级、术前眼压、中央角膜厚度以及同一受试者双眼的使用情况进行了校正。
分析了116例非青光眼患者的161只眼(89例亚洲人、49例白人、12例非洲人、11例西班牙裔)。161只眼中包括81只右眼和80只左眼。89例亚洲眼中包括46例中国人、35例菲律宾人和8例越南人。术前眼压为14.9±3.2 mmHg。术后1天眼压显著升高至16.0±4.9 mmHg(P = 0.037),术后1个月和3个月分别降至12.4±3.1和12.3±3.0 mmHg(均P < 0.0001)。在单变量或多变量聚类线性回归分析中,术后1天、1个月和3个月的眼压变化与CDE测量值均无显著关联(所有P > 0.05)。
超声乳化白内障吸除术中传递到眼内的超声能量(以CDE表示)与术后眼压变化无关。