Department of Ophthalmology, University of California, San Francisco, California 94133-0730, USA.
J Cataract Refract Surg. 2012 Jan;38(1):108-16. doi: 10.1016/j.jcrs.2011.06.037. Epub 2011 Nov 4.
To evaluate anterior chamber biometric factors associated with the degree of angle widening and intraocular pressure (IOP) reduction after phacoemulsification.
University of California, San Francisco, California, USA.
Case series.
Anterior chamber parameters obtained by anterior segment coherence tomography were compared preoperatively and 3 months postoperatively. Measurements included the angle opening distance 500 μm anterior to the scleral spur (AOD500), trabecular-iris space area 500 μm from the scleral spur (TISA500), iris curvature (I-Curv), anterior chamber angle (ACA), trabecular-iris space area, anterior chamber volume, anterior chamber width, and lens vault (LV).
The study enrolled 73 eyes. The mean patient age was 77.45 years ± 7.84 (SD); 65.75% of patients were women. From preoperatively to 3 months postoperatively, the mean AOD500 increased significantly (0.254 ± 0.105 to 0.433 ± 0.108 mm) and the mean IOP decreased significantly (14.97 ± 3.35 to 12.62 ± 3.37 mm Hg) (P<.001). The reduction in IOP was correlated with the increase in AOD500 (r = 0.240, P=.041) and preoperative LV (r = 0.235, P=.045). After adjusting for related factors, AOD500 widening was positively correlated with LV (β = 0.458, P=.044) and I-Curv (β = 0.235, P=.043) and negatively correlated with preoperative TISA500 (β = -0.269, P=.025) and ACA (β = -0.919, P=.027).
Surgically induced AOD widening was significantly correlated with anterior chamber biometric factors. Preoperative LV appears to be a significant factor in angle widening and IOP reduction after phacoemulsification.
评估白内障超声乳化术后前房生物测量参数与房角增宽程度和眼内压(IOP)降低的相关性。
美国加利福尼亚大学旧金山分校。
病例系列。
使用眼前节相干断层扫描仪(AS-OCT)比较术前和术后 3 个月的前房参数。测量指标包括巩膜突前 500μm 的房角开放距离(AOD500)、巩膜突前 500μm 的小梁虹膜空间面积(TISA500)、虹膜曲率(I-Curv)、前房角(ACA)、小梁虹膜空间面积、前房容积、前房宽度和晶状体悬韧带(LV)。
本研究纳入 73 只眼。患者平均年龄 77.45±7.84 岁(标准差);65.75%为女性。从术前到术后 3 个月,平均 AOD500 显著增加(0.254±0.105 至 0.433±0.108mm),平均 IOP 显著降低(14.97±3.35 至 12.62±3.37mmHg)(P<0.001)。IOP 的降低与 AOD500 的增加相关(r=0.240,P=0.041)和术前 LV(r=0.235,P=0.045)。在调整相关因素后,AOD500 增宽与 LV(β=0.458,P=0.044)和 I-Curv(β=0.235,P=0.043)呈正相关,与术前 TISA500(β=-0.269,P=0.025)和 ACA(β=-0.919,P=0.027)呈负相关。
手术诱导的 AOD 增宽与前房生物测量参数显著相关。术前 LV 似乎是白内障超声乳化术后房角增宽和IOP 降低的重要因素。