Suppr超能文献

注意:一种用于具有数字输出的电子变压器的带有相位校正的改进校准系统。

Note: An improved calibration system with phase correction for electronic transformers with digital output.

作者信息

Cheng Han-miao, Li Hong-bin

机构信息

CEEE of Huazhong University of Science and Technology, Wuhan 430074, China.

出版信息

Rev Sci Instrum. 2015 Aug;86(8):086108. doi: 10.1063/1.4929756.

Abstract

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

摘要

现有的采用数据采集卡的电子互感器校准系统无法满足某些实际应用需求,因为该校准系统在接收外部同步信号模式下工作时存在相位测量误差。本文提出了一种具有相位校正功能的改进校准系统方案,以提高相位测量精度。我们采用NI PCI - 4474设计了一个校准系统,该系统有潜力接收外部同步信号并达到极高的精度等级。在中国电力科学研究院进行了精度验证,结果表明该系统超过了0.05级精度。此外,该系统已用于测试全光纤电流互感器的谐波测量精度。在同一过程中,我们使用了现有的校准系统,并给出了测试结果的对比。改进后的系统适用于预期的应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验