Suppr超能文献

[Clinical evaluation of regurgitant blood flow by rapid cine magnetic resonance imaging in patients with valvular heart disease].

作者信息

Onishi S, Fukui S, Atsumi C, Morita R, Fujii K, Kusuoka H, Kitabatake A, Kamada T, Takizawa O

机构信息

Division of Cardiology, Oriono-Izumi Hospital, Osaka.

出版信息

J Cardiol. 1989 Jun;19(2):571-82.

PMID:2636635
Abstract

The clinical usefulness of magnetic resonance imaging (MRI) for evaluating regurgitant blood flow in patients with valvular heart disease was studied. The study subjects comprised three healthy volunteers and nine patients with valvular heart disease (aortic regurgitation 3, mitral regurgitation 2, tricuspid regurgitation 2, and pulmonary regurgitation 2). Five were men and seven were women, ranging in age from 31 to 85 years. Valvular heart disease was diagnosed by two-dimensional Doppler echocardiography. MRI was performed using a 1.5 tesla super-conductive magnet system (MAGNETOM, Siemens AG). A rapid MRI technique (fast low-angle shot [FLASH], flip angle = 30 degrees, TR = 65-90 msec, TE = 10-38 msec) was used to generate 11 frames throughout one cardiac cycle in the transaxial, coronal and oblique planes. These sequential frames were displayed in cine mode on a CRT. 1. Intracavitary blood was imaged as a high signal intensity on gradient echo images, while surrounding cardiac structures had somewhat lower signal intensities. 2. In healthy volunteers, systolic ejection blood flow from the left ventricle was observed on coronal images in the cine mode display. The influx of atrial blood into the left and right ventricles was also clearly observed on transaxial cine images. 3. Aortic regurgitant flow was observed as areas of no signal intensity within the left ventricular cavity during diastole on coronal images. 4. Mitral and tricuspid regurgitations were observed within the left and right atria, respectively, as areas of no signal intensity on transaxial images. The extent of regurgitant flow was determined in the vertical long-axis plane, equivalent to the right anterior oblique projection. 5. The vertical oblique scan was suitable for detecting pulmonary regurgitant flow. These results indicate that the rapid cine MRI technique is a useful tool for noninvasively determining regurgitant blood flow in patients with various valvular heart diseases.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验