PURPOSE

This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging.

MATERIALS AND METHODS

A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1 -weighted images, fast spin-echo T2 -weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images.

RESULTS

Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets.

CONCLUSION

With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

摘要

目的

本研究旨在比较磁共振成像中常见金属正畸托槽产生的金属伪影。

材料与方法

制备一个带有12颗完整前磨牙的干燥下颌骨,使用各种类型的托槽进行十次扫描:使用了美国、3M、Dentaurum和Masel正畸托槽,以及不锈钢(SS)或镍钛(NiTi)丝。随后,获得了三种不同的冠状位和轴位图像序列:自旋回波T1加权图像、快速自旋回波T2加权图像和液体衰减反转恢复图像。在每个序列中,选择信号空洞面积最大的两个连续轴位和冠状位图像。然后在X、Y和Z轴方向上对信号空洞的最大直径进行两次测量。最后,使用单因素方差分析对与不同正畸托槽相关的平均线性值进行分析,并使用独立t检验比较结果,以评估使用SS或NiTi丝是否对图像有显著影响。

结果

在使用SS丝的四种不同品牌正畸托槽中,仅在Z轴上观察到统计学上的显著差异。在使用NiTi丝的托槽中,在所有轴上均观察到统计学上的显著差异。在无镍和含镍托槽之间,仅在Z轴上发现统计学上的显著差异。

结论

在所有轴向上,3M托槽的信号空洞面积较小。总体而言,使用NiTi丝的3M和Dentaurum托槽在所有轴向上产生的伪影比使用SS丝的托槽小。