Suppr超能文献

对中线组织进行非人类灵长类动物全胸肺部照射所产生的平均器官剂量。

Mean Organ Doses Resulting From Non-Human Primate Whole Thorax Lung Irradiation Prescribed to Mid-Line Tissue.

作者信息

Prado Charlotte, Kazi Abdul, Bennett Alexander, MacVittie Thomas, Prado Karl

机构信息

*Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD 21201.

出版信息

Health Phys. 2015 Nov;109(5):367-73. doi: 10.1097/HP.0000000000000336.

Abstract

Multi-organ dose evaluations and the effects of heterogeneous tissue dose calculations have been retrospectively evaluated following irradiation to the whole thorax and lung in non-human primates (NHP). A clinical-based approach was established to evaluate actual doses received in the heart and lungs during whole thorax lung irradiation. Anatomical structure and organ densities have been introduced in the calculations to show the effects of dose distribution through heterogeneous tissue. Mean organ doses received by non-human primates undergoing whole thorax lung irradiations were calculated using a treatment planning system that is routinely used in clinical radiation oncology. The doses received by non-human primates irradiated following conventional dose calculations have been retrospectively reconstructed using computerized tomography-based, heterogeneity-corrected dose calculations. The use of dose volume descriptors for irradiation to organs at risk and tissue exposed to radiation is introduced. Mean and partial-volume doses to lung and heart are presented and contrasted. The importance of exact dose definitions is highlighted, and the relevance of precise dosimetry to establish organ-specific dose response relationships in NHP models of acute and delayed effects of acute radiation exposure is emphasized.

摘要

在对非人类灵长类动物(NHP)进行全胸和肺部照射后,对多器官剂量评估以及非均匀组织剂量计算的影响进行了回顾性评估。建立了一种基于临床的方法来评估全胸肺部照射期间心脏和肺部实际接受的剂量。在计算中引入了解剖结构和器官密度,以显示通过非均匀组织的剂量分布效果。使用临床放射肿瘤学中常规使用的治疗计划系统计算接受全胸肺部照射的非人类灵长类动物的平均器官剂量。使用基于计算机断层扫描的、经非均匀性校正的剂量计算方法,对按照传统剂量计算进行照射的非人类灵长类动物所接受的剂量进行了回顾性重建。介绍了用于照射危及器官和受辐射组织的剂量体积描述符。给出并对比了肺部和心脏的平均剂量和部分体积剂量。强调了精确剂量定义的重要性,并强调了精确剂量测定对于在急性辐射暴露的急性和延迟效应的NHP模型中建立器官特异性剂量反应关系的相关性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ac8d/4593315/e65e7190bbd9/nihms-696707-f0001.jpg

相似文献

引用本文的文献

7
An injectable dosimeter for small animal irradiations.一种用于小动物辐照的可注射剂量计。
Phys Med Biol. 2019 Sep 17;64(18):18NT01. doi: 10.1088/1361-6560/ab3bb9.

本文引用的文献

1
The Importance of Dosimetry Standardization in Radiobiology.放射生物学中剂量测定标准化的重要性。
J Res Natl Inst Stand Technol. 2013 Dec 30;118:403-18. doi: 10.6028/jres.118.021. eCollection 2013.
9
Radiation dose-volume effects in the lung.肺部的放射剂量-体积效应。
Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S70-6. doi: 10.1016/j.ijrobp.2009.06.091.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验