Suppr超能文献

与标准种植体相比,评估在下颌骨高度降低的无牙患者中使用4毫米超短种植体:12个月的结果。

Evaluation of extrashort 4-mm implants in mandibular edentulous patients with reduced bone height in comparison with standard implants: a 12-month results.

作者信息

Calvo-Guirado José Luis, López Torres José Alberto, Dard Michel, Javed Fawad, Pérez-Albacete Martínez Carlos, Maté Sánchez de Val José Eduardo

机构信息

International Dentistry Research Cathedra, Universidad Católica San Antonio de Murcia (UCAM), Murcia, Spain.

New York University, New York City, NY, USA.

出版信息

Clin Oral Implants Res. 2016 Jul;27(7):867-874. doi: 10.1111/clr.12704. Epub 2015 Oct 3.

Abstract

OBJECTIVE

The aim of this research was to evaluate the primary stability, the marginal bone loss, the survival, and the success criteria, of 4-mm-length implants compared with implants of conventional length supporting fixed prostheses.

MATERIALS AND METHODS

Ten patients were selected for treatment of their atrophic edentulous jaws. Each patient received the following treatment: six dental implants were inserted, two anterior implants of conventional length (10-mm) in the interforaminal area and four posterior short implants of 4-mm length (Standard Plus, Roxolid, SLActive, Institut Straumann AG). The implants supported screw-retained fixed complete dentures. Examinations were conducted at day 0, three, six, and twelve months after surgery for the evaluation of the implant primary stability, secondary stability, crestal bone loss and survival by clinical evaluations, insertion torque values, resonance frequency analysis (RFA), and periapical radiography, respectively.

RESULTS

Sixty implants were inserted in ten patients. Mean insertion torque was slightly lower for 4-mm implants than 10-mm implants (38.1 Ncm vs. 42.2 Ncm) but without statistically significant difference. Implant stability was similar for extrashort and conventional implants. Marginal bone loss was similar for both groups for all the time periods. One short implant was lost before loading. The survival rates twelve months after implant placement were of 97.5% and 100% for short and conventional implants, respectively. Similarly, implant stability as measured by RFA was nonsignificantly lower for the 4-mm implants compared to the 10-mm implants. The marginal bone loss was lower for short implants three, six, and twelve months after the surgery without statistical significant difference.

CONCLUSIONS

Within the limitations of this study, we conclude that short dental implants (8 mm or less in length) supporting single crowns or fixed bridges are a feasible treatment option with radiographic and clinical success rates similar to longer implants for patients with compromised ridges. Long-term data with larger number of implants and subjects are needed to confirm these preliminary results.

摘要

目的

本研究旨在评估长度为4毫米的种植体与支持固定修复体的传统长度种植体相比的初期稳定性、边缘骨吸收、存留率及成功标准。

材料与方法

选择10例萎缩性无牙颌患者进行治疗。每位患者接受如下治疗:植入6枚牙种植体,在双侧颏孔间区域植入2枚传统长度(10毫米)的前牙种植体,以及4枚长度为4毫米的后牙短种植体(标准加强型、Roxolid、SLActive,士卓曼公司)。这些种植体支持螺丝固位的固定全口义齿。分别在术后第0天、3个月、6个月和12个月进行检查,通过临床评估、植入扭矩值、共振频率分析(RFA)和根尖片评估种植体的初期稳定性、二期稳定性、牙槽嵴顶骨吸收和存留情况。

结果

10例患者共植入60枚种植体。4毫米种植体的平均植入扭矩略低于10毫米种植体(38.1牛厘米对42.2牛厘米),但无统计学显著差异。超短种植体和传统种植体的种植体稳定性相似。两组在所有时间段的边缘骨吸收情况相似。1枚短种植体在加载前脱落。种植体植入12个月后的存留率,短种植体为97.5%,传统种植体为100%。同样,通过RFA测量,4毫米种植体的种植体稳定性相比10毫米种植体略低,但无统计学显著差异。术后3个月、6个月和12个月时,短种植体的边缘骨吸收较低,但无统计学显著差异。

结论

在本研究的局限性范围内,我们得出结论,对于牙槽嵴条件不佳的患者,支持单冠或固定桥的短牙种植体(长度为8毫米或更短)是一种可行的治疗选择,其影像学和临床成功率与较长种植体相似。需要更多种植体和受试者的长期数据来证实这些初步结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验