Suppr超能文献

一种基于比尔-朗伯定律的电子断层扫描图像配准快速交叉验证方法。

A fast cross-validation method for alignment of electron tomography images based on Beer-Lambert law.

作者信息

Yan Rui, Edwards Thomas J, Pankratz Logan M, Kuhn Richard J, Lanman Jason K, Liu Jun, Jiang Wen

机构信息

Markey Center for Structural Biology, Department of Biological Sciences, Purdue University, West Lafayette, IN 47907, USA.

Department of Pathology and Laboratory Medicine, University of Texas Medical School at Houston, Houston, TX 77030, USA.

出版信息

J Struct Biol. 2015 Nov;192(2):297-306. doi: 10.1016/j.jsb.2015.10.004. Epub 2015 Oct 9.

Abstract

In electron tomography, accurate alignment of tilt series is an essential step in attaining high-resolution 3D reconstructions. Nevertheless, quantitative assessment of alignment quality has remained a challenging issue, even though many alignment methods have been reported. Here, we report a fast and accurate method, tomoAlignEval, based on the Beer-Lambert law, for the evaluation of alignment quality. Our method is able to globally estimate the alignment accuracy by measuring the goodness of log-linear relationship of the beam intensity attenuations at different tilt angles. Extensive tests with experimental data demonstrated its robust performance with stained and cryo samples. Our method is not only significantly faster but also more sensitive than measurements of tomogram resolution using Fourier shell correlation method (FSCe/o). From these tests, we also conclude that while current alignment methods are sufficiently accurate for stained samples, inaccurate alignments remain a major limitation for high resolution cryo-electron tomography.

摘要

在电子断层扫描中,倾斜序列的精确对齐是获得高分辨率三维重建的关键步骤。然而,尽管已经报道了许多对齐方法,但对齐质量的定量评估仍然是一个具有挑战性的问题。在此,我们报告一种基于比尔-朗伯定律的快速准确方法tomoAlignEval,用于评估对齐质量。我们的方法能够通过测量不同倾斜角度下光束强度衰减的对数线性关系的优度来全局估计对齐精度。对实验数据的广泛测试证明了其在染色和冷冻样品上的稳健性能。我们的方法不仅比使用傅里叶壳相关法(FSCe/o)测量断层分辨率的速度快得多,而且更灵敏。从这些测试中,我们还得出结论,虽然当前的对齐方法对于染色样品足够准确,但不准确的对齐仍然是高分辨率冷冻电子断层扫描的主要限制。

相似文献

1
A fast cross-validation method for alignment of electron tomography images based on Beer-Lambert law.
J Struct Biol. 2015 Nov;192(2):297-306. doi: 10.1016/j.jsb.2015.10.004. Epub 2015 Oct 9.
3
Conical Fourier shell correlation applied to electron tomograms.
J Struct Biol. 2015 May;190(2):215-23. doi: 10.1016/j.jsb.2015.03.010. Epub 2015 Apr 3.
4
Implementation of a cryo-electron tomography tilt-scheme optimized for high resolution subtomogram averaging.
J Struct Biol. 2017 Feb;197(2):191-198. doi: 10.1016/j.jsb.2016.06.007. Epub 2016 Jun 14.
5
Cryo-tomography tilt-series alignment with consideration of the beam-induced sample motion.
J Struct Biol. 2018 Jun;202(3):200-209. doi: 10.1016/j.jsb.2018.02.001. Epub 2018 Feb 3.
6
Refinement procedure for the image alignment in high-resolution electron tomography.
Ultramicroscopy. 2011 Aug-Oct;111(9-10):1512-20. doi: 10.1016/j.ultramic.2011.06.001. Epub 2011 Jun 21.
7
Consideration of sample motion in cryo-tomography based on alignment residual interpolation.
J Struct Biol. 2019 Mar 1;205(3):1-6. doi: 10.1016/j.jsb.2019.01.005. Epub 2019 Jan 26.
8
Markerauto2: A fast and robust fully automatic fiducial marker-based tilt series alignment software for electron tomography.
Structure. 2024 Sep 5;32(9):1507-1518.e5. doi: 10.1016/j.str.2024.05.020. Epub 2024 Jun 26.
9
Assessing the benefits of focal pair cryo-electron tomography.
J Struct Biol. 2012 May;178(2):88-97. doi: 10.1016/j.jsb.2011.10.004. Epub 2011 Oct 25.
10
Quantifying resolution limiting factors in subtomogram averaged cryo-electron tomography using simulations.
J Struct Biol. 2014 Aug;187(2):103-111. doi: 10.1016/j.jsb.2014.06.007. Epub 2014 Jul 3.

本文引用的文献

1
Thon rings from amorphous ice and implications of beam-induced Brownian motion in single particle electron cryo-microscopy.
Ultramicroscopy. 2015 Nov;158:26-32. doi: 10.1016/j.ultramic.2015.05.017. Epub 2015 May 27.
2
Quantifying resolution limiting factors in subtomogram averaged cryo-electron tomography using simulations.
J Struct Biol. 2014 Aug;187(2):103-111. doi: 10.1016/j.jsb.2014.06.007. Epub 2014 Jul 3.
3
A marker-free automatic alignment method based on scale-invariant features.
J Struct Biol. 2014 Apr;186(1):167-80. doi: 10.1016/j.jsb.2014.02.011. Epub 2014 Feb 27.
4
A new correlation based alignment technique for use in electron tomography.
Ultramicroscopy. 2013 Dec;135:56-63. doi: 10.1016/j.ultramic.2013.05.012. Epub 2013 Jun 5.
5
Protein secondary structure determination by constrained single-particle cryo-electron tomography.
Structure. 2012 Dec 5;20(12):2003-13. doi: 10.1016/j.str.2012.10.016.
6
Local thickness measurement through scattering contrast and electron energy-loss spectroscopy.
Micron. 2012 Jan;43(1):8-15. doi: 10.1016/j.micron.2011.07.003. Epub 2011 Jul 14.
7
A dose-rate effect in single-particle electron microscopy.
J Struct Biol. 2008 Jan;161(1):92-100. doi: 10.1016/j.jsb.2007.09.017. Epub 2007 Oct 1.
8
EMAN2: an extensible image processing suite for electron microscopy.
J Struct Biol. 2007 Jan;157(1):38-46. doi: 10.1016/j.jsb.2006.05.009. Epub 2006 Jun 8.
9
Automatic TEM image alignment by trifocal geometry.
J Microsc. 2006 Apr;222(Pt 1):1-14. doi: 10.1111/j.1365-2818.2006.01545.x.
10
Accurate marker-free alignment with simultaneous geometry determination and reconstruction of tilt series in electron tomography.
Ultramicroscopy. 2006 Feb;106(3):240-54. doi: 10.1016/j.ultramic.2005.07.007. Epub 2005 Aug 9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验