Scelza Pantaleo, Harry Davidowicz, Silva Licinio Esmeraldo da, Barbosa Igor Bastos, Scelza Miriam Zaccaro
Department of Endodontics, School of Dentistry, Universidade Federal Fluminense, Niterói, RJ, Brazil.
Centro de Estudos Treinamento e Aperfeiçoamento em Odontologia, São Paulo, SP, Brazil.
Braz Oral Res. 2015;29:1-7. doi: 10.1590/1807-3107BOR-2015.vol29.0107. Epub 2015 Oct 20.
The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.
本研究旨在比较评估WaveOne(登士柏迈福,瑞士拜莱格)25-08器械和Reciproc(VDW,德国慕尼黑)25-08器械在45°时的抗弯曲性能、静态和动态循环疲劳寿命以及骨折类型。共测试了来自三个不同批次的60根镍钛(NiTi)器械(30根Reciproc和30根WaveOne),每根器械长度均为25 mm。通过使用万能试验机进行悬臂弯曲试验的结果来评估抗弯曲性能。使用定制设备进行静态和动态循环疲劳测试。对于静态和动态测试,使用了一个铸造的Ni-Cr-Mo-Ti合金金属块,其人工根管直径为1.77 mm,总长度为20.00 mm。使用扫描电子显微镜确定骨折类型。对结果进行统计分析。WaveOne器械的柔韧性低于Reciproc(p < 0.05)。Reciproc器械在静态和动态循环疲劳测试中表现出更好的抗性(p < 0.05)。器械的横截面和几何形状是其抗弯曲和循环骨折的重要因素。两种器械均表现出韧性骨折特征。可以得出结论,Reciproc 25-08器械比WaveOne 25-08器械更耐静态和动态循环疲劳,而WaveOne 25-08器械的柔韧性较差。弯曲和抗循环骨折受器械几何形状和横截面的影响。两种器械均表现出韧性骨折特征。