Suppr超能文献

Tango-Endo、WaveOne GOLD和Reciproc镍钛器械的循环疲劳寿命。

Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments.

作者信息

Yılmaz Koray, Özyürek Taha

机构信息

Samsun Oral and Dental Health Hospital, Samsun, Turkey.

Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.

出版信息

Restor Dent Endod. 2017 May;42(2):134-139. doi: 10.5395/rde.2017.42.2.134. Epub 2017 Apr 11.

Abstract

OBJECTIVES

To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature.

MATERIALS AND METHODS

Reciproc R25, WaveOne GOLD Primary, and Tango-Endo instruments were included in this study ( = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, 60°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and Dunn tests were used for the statistical analysis of data in SPSS 21.0 software.

RESULTS

Tango-Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life ( < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files ( > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files ( < 0.05).

CONCLUSIONS

Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.

摘要

目的

通过不同弯曲角度的人工根管,比较Tango-Endo、WaveOne GOLD和Reciproc镍钛器械在静态模型下的疲劳寿命。

材料与方法

本研究纳入Reciproc R25、WaveOne GOLD Primary和Tango-Endo器械(n = 20)。所有器械在由内径1.5 mm、弯曲角度为45°、60°和90°且曲率半径为5 mm的不锈钢制成的人工根管中旋转,直至器械折断,使用数字计时器以秒为单位记录折断时间。数据采用Kruskal-Wallis检验进行分析,并使用Dunn检验在SPSS 21.0软件中对数据进行统计分析。

结果

在疲劳寿命方面,发现Tango-Endo锉的值显著高于WaveOne GOLD和Reciproc锉(P < 0.05)。然而,Reciproc锉和WaveOne GOLD锉的疲劳寿命之间无统计学显著差异(P > 0.05)。确定增加不锈钢根管的弯曲角度会导致所有三种锉的疲劳寿命显著降低(P < 0.05)。

结论

在本研究的局限性内,Tango-Endo在不同弯曲角度根管中的循环疲劳寿命在统计学上高于Reciproc和WaveOne GOLD。