Suppr超能文献

无网格床边胸部X线摄影的迭代散射校正:胸部模体的性能

ITERATIVE SCATTER CORRECTION FOR GRID-LESS BEDSIDE CHEST RADIOGRAPHY: PERFORMANCE FOR A CHEST PHANTOM.

作者信息

Mentrup Detlef, Jockel Sascha, Menser Bernd, Neitzel Ulrich

机构信息

Diagnostic X-Ray, Philips Healthcare DMC GmbH, Röntgenstraße 24, 22335 Hamburg, Germany

Diagnostic X-Ray, Philips Healthcare DMC GmbH, Röntgenstraße 24, 22335 Hamburg, Germany.

出版信息

Radiat Prot Dosimetry. 2016 Jun;169(1-4):308-12. doi: 10.1093/rpd/ncv432. Epub 2015 Oct 19.

Abstract

The aim of this work was to experimentally compare the contrast improvement factors (CIFs) of a newly developed software-based scatter correction to the CIFs achieved by an antiscatter grid. To this end, three aluminium discs were placed in the lung, the retrocardial and the abdominal areas of a thorax phantom, and digital radiographs of the phantom were acquired both with and without a stationary grid. The contrast generated by the discs was measured in both images, and the CIFs achieved by grid usage were determined for each disc. Additionally, the non-grid images were processed with a scatter correction software. The contrasts generated by the discs were determined in the scatter-corrected images, and the corresponding CIFs were calculated. The CIFs obtained with the grid and with the software were in good agreement. In conclusion, the experiment demonstrates quantitatively that software-based scatter correction allows restoring the image contrast of a non-grid image in a manner comparable with an antiscatter grid.

摘要

这项工作的目的是通过实验比较新开发的基于软件的散射校正的对比度改善因子(CIF)与防散射格栅所实现的CIF。为此,在胸部模型的肺部、心后区和腹部区域放置了三个铝盘,并在使用和不使用固定格栅的情况下采集了模型的数字射线照片。在两张图像中测量铝盘产生的对比度,并确定每个铝盘使用格栅所实现的CIF。此外,对无格栅图像使用散射校正软件进行处理。在散射校正后的图像中确定铝盘产生的对比度,并计算相应的CIF。使用格栅和软件获得的CIF高度一致。总之,该实验定量地证明,基于软件的散射校正能够以与防散射格栅相当的方式恢复无格栅图像的图像对比度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验