Suppr超能文献

数字乳腺断层合成与乳腺超声:在传统数字乳腺摄影中分类为0类的致密型乳腺中的额外作用。

Digital breast tomosynthesis and breast ultrasound: Additional roles in dense breasts with category 0 at conventional digital mammography.

作者信息

Lee Won Kyung, Chung Jin, Cha Eun-Suk, Lee Jee Eun, Kim Jeoung Hyun

机构信息

Department of Radiology, Ewha Womans University, School of Medicine, Seoul, South Korea.

Department of Radiology, Ewha Womans University, School of Medicine, Seoul, South Korea.

出版信息

Eur J Radiol. 2016 Jan;85(1):291-296. doi: 10.1016/j.ejrad.2015.09.026. Epub 2015 Sep 30.

Abstract

PURPOSE

To compare the diagnostic performances of digital breast tomosynthesis (DBT) and ultrasound for the dense breasts with category 0 at conventional digital mammography.

MATERIALS AND METHODS

This retrospective study was approved by the institutional review board, and informed consent was waived. Among the 1103 patients who underwent screening digital mammography at our institution, 769 (69.7%) patients had dense breasts. Of the 769 patients, 229 (29.8%) lesions were categorized as 0. DBT, breast ultrasound and digital mammography were performed in 108 (47.2%) patients. BI-RADS final assessments for DBT and ultrasound were recorded. Categories 1-3 were clinically considered as benign, and categories 4 and 5 were clinically considered as malignant. The diagnostic performances of breast ultrasound and DBT were correlated with final pathologic reports or follow-up images.

RESULTS

Among 108 lesions, 17 (15.7%) were malignant and 91 (84.3%) were benign. Sensitivity was 100% for both ultrasound (17/17) and DBT (17/17) and negative predictive value was also 100% for both ultrasound (49/49) and DBT (74/74). Specificity and positive predictive value for ultrasound were 53.9% (49/91) and 28.8% (17/59), respectively. Specificity and positive predictive value for DBT were 81.3% (74/91) and 50% (17/34), respectively. DBT showed higher diagnostic accuracy than that of breast ultrasound (DBT: 84.3%, 91/108; ultrasound: 61.1%, 66/108; p<0.001). The benign biopsy rate of DBT (50%, 17/34) was lower than that of ultrasound (71.2%, 42/59).

CONCLUSION

DBT showed better diagnostic performance than breast ultrasound for dense breasts with category 0. DBT may reduce the benign biopsy rate and short term follow-up.

摘要

目的

比较数字乳腺断层合成(DBT)和超声对传统数字乳腺摄影分类为0类的致密乳腺的诊断性能。

材料与方法

本回顾性研究经机构审查委员会批准,无需知情同意。在我院接受筛查数字乳腺摄影的1103例患者中,769例(69.7%)为致密乳腺。在这769例患者中,229个(29.8%)病变被分类为0类。108例(47.2%)患者接受了DBT、乳腺超声和数字乳腺摄影检查。记录DBT和超声的BI-RADS最终评估结果。1-3类在临床上被视为良性,4类和5类在临床上被视为恶性。乳腺超声和DBT的诊断性能与最终病理报告或随访影像相关。

结果

在108个病变中,17个(15.7%)为恶性,91个(84.3%)为良性。超声(17/17)和DBT(17/17)的敏感性均为100%,超声(49/49)和DBT(74/74)的阴性预测值也均为100%。超声的特异性和阳性预测值分别为53.9%(49/91)和28.8%(17/59)。DBT的特异性和阳性预测值分别为81.3%(74/91)和50%(17/34)。DBT的诊断准确性高于乳腺超声(DBT:84.3%,91/108;超声:61.1%,66/108;p<0.001)。DBT的良性活检率(50%,17/34)低于超声(71.2%,42/59)。

结论

对于分类为0类的致密乳腺,DBT的诊断性能优于乳腺超声。DBT可能会降低良性活检率和缩短短期随访时间。