Lim Serene Liqing, Jung Jacqueline Jingjin, Yu Su Ling, Rajesh Hemashree
Centre of Assisted Reproduction, Department of Obstetrics & Gynaecology, Singapore General Hospital, Singapore, Singapore.
Centre of Assisted Reproduction, Department of Obstetrics & Gynaecology, Singapore General Hospital, Singapore, Singapore.
Eur J Obstet Gynecol Reprod Biol. 2015 Dec;195:168-172. doi: 10.1016/j.ejogrb.2015.10.008. Epub 2015 Oct 23.
A randomized controlled selective cross-over trial was performed to compare the diagnostic yield and efficacy of ExEm foam (HyFoSy) with saline medium (HyCoSy) as a contrast agent for hysterosalping-contrast sonography in subfertile patients.
40 patients were randomized into HyCoSy with saline medium and HyFoSy with ExEm foam. Tubal patency were assessed according to pre-determined objective criteria that classified tubes based on degree of certainty in tubal patency. Selective cross-over testing with the other medium was performed in patients who had at least one possibly occluded or unexaminable tube on the initial test.
80 tubes were evaluated. On initial testing, the proportion of tubes that were classified as patent was higher with HyFoSy compared to HyCoSy (70.0% vs 40.0%, p=0.01). A higher proportion of patients in the HyCoSy group required crossover testing [80.0% (16/20) vs 45.0% (9/20), p=0.02]. On cross-over testing, 41.7% (10/24) of possibly occluded or unexaminable tubes in the HyCoSy group were re-classified as patent when examined with Ex-Em foam, compared to 8.3% (1/12) of possibly occluded or unexaminable tubes in the HyFoSy group (p=0.03).
ExEm foam medium (HyFoSy) might improve the diagnostic yield and efficacy over saline medium (HyCoSy) for hysterosalpingsonography.
进行一项随机对照选择性交叉试验,以比较ExEm泡沫(子宫输卵管造影超声检查[HyFoSy])与生理盐水介质(子宫输卵管声学造影[HyCoSy])作为造影剂在不育症患者子宫输卵管造影超声检查中的诊断率和效果。
40例患者被随机分为接受生理盐水介质HyCoSy组和接受ExEm泡沫HyFoSy组。根据预先确定的客观标准评估输卵管通畅情况,该标准根据输卵管通畅的确定程度对输卵管进行分类。对初始检查时至少有一根可能阻塞或无法检查的输卵管的患者,用另一种介质进行选择性交叉测试。
共评估了80根输卵管。在初始检查中,与HyCoSy相比,HyFoSy分类为通畅的输卵管比例更高(70.0%对40.0%,p=0.01)。HyCoSy组中需要交叉测试的患者比例更高[80.0%(16/20)对45.0%(9/20),p=0.02]。在交叉测试中,HyCoSy组中41.7%(10/24)可能阻塞或无法检查的输卵管在用Ex-Em泡沫检查时重新分类为通畅,而HyFoSy组中这一比例为8.3%(1/12)(p=0.03)。
对于子宫输卵管造影超声检查,ExEm泡沫介质(HyFoSy)可能比生理盐水介质(HyCoSy)提高诊断率和效果。