Suppr超能文献

Dosimetric impact of different multileaf collimators on prostate intensity modulated treatment planning.

作者信息

Orlandini Lucia Clara, Betti Margherita, Fulcheri Christian, Coppola Marianna, Cionini Luca

机构信息

Medical Physics Unit, Centro Oncologico Fiorentino, Via A. Ragionieri 101, 50019 Sesto Fiorentino, Italy.

Radiation Oncology Department, Centro Oncologico Fiorentino, Via A. Ragionieri 101, 50019 Sesto Fiorentino, Italy.

出版信息

Rep Pract Oncol Radiother. 2015 Sep-Oct;20(5):358-64. doi: 10.1016/j.rpor.2015.06.005. Epub 2015 Sep 29.

Abstract

AIM

The main purpose of this study is to perform a dosimetric comparison on target volumes and organs at risks (OARs) between prostate intensity modulated treatment plans (IMRT) optimized with different multileaf collimators (MLCs).

BACKGROUND

The use of MLCs with a small leaf width in the IMRT optimization may improve conformity around the tumor target whilst reducing the dose to normal tissues.

MATERIALS AND METHODS

Two linacs mounting MLCs with 5 and 10 mm leaf-width, respectively, implemented in Pinnacle(3) treatment planning system were used for this work. Nineteen patients with prostate carcinoma undergoing a radiotherapy treatment were enrolled. Treatment planning with different setup arrangements (7 and 5 beams) were performed for each patient and each machine. Dose volume histograms (DVHs) cut-off points were used in the treatment planning comparison.

RESULTS

Comparable planning target volume (PTV) coverage was obtained with 7- and 5-beam configuration (both with 5 and 10 mm MLC leaf-width). The comparison of bladder and rectum DVH cut-off points for the 5-beam arrangement shows that 52.6% of the plans optimized with a larger leaf-width did not satisfy at least one of the OARs' constraints. This percentage is reduced to 10.5% for the smaller leaf-width. If a 7-beam arrangement is used the value of 52.6% decreases to 21.1% while the value of 10.5% remains unchanged.

CONCLUSION

MLCs collimators with different widths and number of leaves lead to a comparable prostate treatment planning if a proper adjustment is made of the number of gantry angles.

摘要

相似文献

1
Dosimetric impact of different multileaf collimators on prostate intensity modulated treatment planning.
Rep Pract Oncol Radiother. 2015 Sep-Oct;20(5):358-64. doi: 10.1016/j.rpor.2015.06.005. Epub 2015 Sep 29.
2
Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions.
Radiother Oncol. 2005 Apr;75(1):106-11. doi: 10.1016/j.radonc.2005.02.007. Epub 2005 Apr 18.
7
Stereotactic IMRT for prostate cancer: dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT.
J Appl Clin Med Phys. 2004 Spring;5(2):29-41. doi: 10.1120/jacmp.v5i2.1989. Epub 2004 Apr 1.
8
Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy.
Int J Radiat Oncol Biol Phys. 2006 Jan 1;64(1):301-20. doi: 10.1016/j.ijrobp.2005.08.023. Epub 2005 Nov 14.

引用本文的文献

1
Dosimetric sensitivity of leaf width on volumetric modulated arc therapy plan quality: an objective approach.
Rep Pract Oncol Radiother. 2022 Mar 22;27(1):76-85. doi: 10.5603/RPOR.a2022.0001. eCollection 2022.
2
A strategy to determine off-axis dosimetric leaf gap using OSLD and EPID.
Rep Pract Oncol Radiother. 2021 Dec 30;26(6):1019-1028. doi: 10.5603/RPOR.a2021.0117. eCollection 2021.

本文引用的文献

2
3
The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome.
Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155-60. doi: 10.1016/j.ijrobp.2009.08.074.
5
Planning and delivery of intensity-modulated radiation therapy.
Med Phys. 2008 Dec;35(12):5233-41. doi: 10.1118/1.3002305.
6
9
Two-dimensional ionization chamber arrays for IMRT plan verification.
Med Phys. 2006 Apr;33(4):1005-15. doi: 10.1118/1.2179167.
10
Evaluation of the gamma dose distribution comparison method.
Med Phys. 2003 Sep;30(9):2455-64. doi: 10.1118/1.1598711.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验