Animal. 2016 Apr;10(4):643-8. doi: 10.1017/S1751731115002451. Epub 2015 Nov 11.
The objective of this work was to investigate the evaluation of swine colostrum immunoglobulin G (IgG) concentration using the Brix refractometer. Colostrum samples were collected across all teats, from 124 sows of mixed parities. According to sampling time, three categories were created: samples available from 9 h before the onset of parturition until the first piglet was born were classified as before farrowing; samples collected after the first birth until 4 h later were classified as during farrowing; and finally samples collected from this point until 14 h after parturition, were classified as after farrowing. Samples were drawn and divided into three portions; one was immediately analyzed, a second was refrigerated and the third was frozen at -20°C. Fresh and refrigerated colostrum samples were analyzed at the farm with a Brix refractometer. IgG content of frozen samples was analyzed using a Brix refractometer, with a subset of 42 samples also tested with a commercially available radial immune diffusion (RID) kit. The Brix percentage ranged from 18.3% to 33.2%. Brix percentage repeatability, assessed by the intraclass correlation coefficient (ICC), was very strong (fresh ICC=0.98, refrigerated ICC=0.88 and frozen ICC=0.99). One-way repeated-measures ANOVA showed that storage temperature did not affect BRIX percentage of colostrum IgG (P>0.05). ANOVA results show a significant effect of sampling time on colostrum immunoglobulin concentration, measured with both Brix and RID (Brix: P<0.003; RID: P<0.05). Immunoglobulin G concentration measured by RID ranged from 13.27 to 35.08 mg/ml. Pearson correlation coefficient revealed that Brix percentage was positively correlated (r=0.56, P<0.001) with RID results (regression equation: RID=1.01 (±0.2) Brix -1.94 (±5.66); R 2=0.31). The results of this study indicate that the Brix refractometer provides a simple, fast and inexpensive estimation of colostrum IgG in sows.
本研究旨在探讨利用 Brix 折射仪评估猪初乳免疫球蛋白 G(IgG)浓度。从 124 头不同胎次的母猪的所有乳头上采集初乳样本。根据采样时间,将其分为三类:从分娩开始前 9 小时至第一头仔猪出生的样本归类为产前;从第一头仔猪出生到 4 小时后的样本归类为分娩中;最后从这个时间点到分娩后 14 小时的样本归类为产后。采集样本并分为三份;一份立即分析,一份冷藏,一份冷冻在-20°C。新鲜和冷藏的初乳样本在农场用 Brix 折射仪进行分析。用 Brix 折射仪分析冷冻样本的 IgG 含量,其中 42 个样本的子集也用商业上可用的放射免疫扩散(RID)试剂盒进行测试。Brix 百分比范围为 18.3%至 33.2%。通过组内相关系数(ICC)评估的 Brix 百分比重复性非常强(新鲜 ICC=0.98,冷藏 ICC=0.88,冷冻 ICC=0.99)。单向重复测量方差分析显示,储存温度对初乳 IgG 的 Brix 百分比没有影响(P>0.05)。方差分析结果表明,采样时间对 Brix 和 RID 测量的初乳免疫球蛋白浓度有显著影响(Brix:P<0.003;RID:P<0.05)。RID 测量的 IgG 浓度范围为 13.27 至 35.08 mg/ml。Pearson 相关系数显示,Brix 百分比与 RID 结果呈正相关(r=0.56,P<0.001)(回归方程:RID=1.01(±0.2)Brix-1.94(±5.66);R 2=0.31)。本研究结果表明,Brix 折射仪可简单、快速且经济地估计母猪初乳中的 IgG。