Suppr超能文献

评估折射仪法(Brix refractometer)估算牛初乳中免疫球蛋白 G 浓度。

Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum.

机构信息

APC Inc., Ankeny, IA 50021, USA.

出版信息

J Dairy Sci. 2013 Feb;96(2):1148-55. doi: 10.3168/jds.2012-5823. Epub 2012 Nov 29.

Abstract

Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Samples of first-milking MC were collected from 7 dairy farms in Maine, New Hampshire, Vermont, and Connecticut (n=84) and 1 dairy farm in California (n=99). The MC was milked from the cow at 6.1 ± 5.6h postparturition and a sample was evaluated for Brix percentage by using an optical refractometer. Two additional samples (30 mL) were collected from the milk bucket, placed in vials, and frozen before analysis of total IgG by radial immunodiffusion (RID) using commercially available plates and by turbidimetric immunoassay (TIA). The second sample was analyzed for total bacterial counts and coliform counts at laboratories in New York (Northeast samples) and California (California samples). The Brix percentage (mean ± SD) was 23.8 ± 3.5, IgG concentration measured by RID was 73.4 ± 26.2g/L, and IgG concentration measured by TIA was 67.5 ± 25.0 g/L. The Brix percentage was highly correlated (r=0.75) with IgG analyzed by RID. The Brix percentage cut point to define high- or low-quality colostrum (50 g of IgG/L measured by RID) that classified more samples correctly given the proportion of high- (86%) and low-quality (14%) samples in this study was 21%, which is slightly lower than other recent estimates of Brix measurements. At this cut point, the test sensitivity, specificity, positive and negative predictive values, and accuracy were 92.9, 65.5, 93.5, 63.3, and 88.5%, respectively. Measurement of IgG by TIA correlated with Brix (r=0.63) and RID (r=0.87); however, TIA and RID methods of IgG measurement were not consistent throughout the range of samples tested. We conclude that Brix measurement of total solids in fresh MC is an inexpensive, rapid, and satisfactorily accurate method of estimating IgG concentration. A cut point of 21% Brix to estimate samples of MC >50 g/L was most appropriate for our data. Measurement of IgG in MC by TIA differed from measurement by RID.

摘要

使用 Brix 折射仪测量折射度已被提议用于估计牛初乳(MC)中的 IgG 浓度。与其他估计 IgG 浓度的方法相比,折射仪具有优势,因为 Brix 折射仪价格低廉、易于获得、不易碎且对初乳温度、季节和其他因素的变化不太敏感。从缅因州、新罕布什尔州、佛蒙特州和康涅狄格州的 7 个奶牛场(n=84)和加利福尼亚州的 1 个奶牛场(n=99)采集了第一次挤奶的 MC 样本。MC 在产后 6.1 ± 5.6 小时从奶牛中挤出,并使用光学折射仪评估 Brix 百分比。从奶桶中采集另外两个(30 毫升)样本,放入小瓶中,在纽约(东北样本)和加利福尼亚(加利福尼亚样本)的实验室中通过商业上可获得的平板进行放射免疫扩散(RID)分析之前冷冻,通过比浊免疫测定(TIA)分析总 IgG。第二个样本分析了总细菌计数和大肠菌群计数。Brix 百分比(平均值±SD)为 23.8 ± 3.5,通过 RID 测量的 IgG 浓度为 73.4 ± 26.2g/L,通过 TIA 测量的 IgG 浓度为 67.5 ± 25.0 g/L。Brix 百分比与通过 RID 分析的 IgG 高度相关(r=0.75)。Brix 百分比的截断值为 50g/L 的高或低质量初乳(通过 RID 测量),该截断值可正确分类更多的样本,因为本研究中高质量(86%)和低质量(14%)样本的比例较高,为 21%,略低于其他最近的 Brix 测量估计值。在该截断点,测试的灵敏度、特异性、阳性和阴性预测值和准确性分别为 92.9%、65.5%、93.5%、63.3%和 88.5%。TIA 测量的 IgG 与 Brix(r=0.63)和 RID(r=0.87)相关;然而,TIA 和 RID 方法的 IgG 测量在整个测试样本范围内并不一致。我们得出结论,Brix 测量新鲜 MC 中的总固体是一种廉价、快速且令人满意的准确估计 IgG 浓度的方法。对于我们的数据,21%Brix 的截断值最适合估计 MC 样本>50g/L。TIA 测量的 IgG 与 RID 测量的 IgG 不同。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验