Nojavan Saeed, Asadi Sakine
Faculty of Chemistry, ShahidBeheshti University, Tehran, Iran.
Electrophoresis. 2016 Feb;37(4):587-94. doi: 10.1002/elps.201500455. Epub 2015 Dec 21.
Simultaneous extraction of acidic and basic analytes from a sample is seen to be a challenging task. In this work, a novel and efficient electromembrane extraction (EME) method based on two separate cells was applied to simultaneously extract and preconcentrate two acidic drugs (naproxen and ibuprofen) along with a basic drug (ketamine). Once both cells were filled with the sample solution, basic drug was extracted from one cell with the other cell used to extract acidic drugs. The employed supported liquid membranes for the extraction of acidic and basic drugs were 2-ethyl hexanol and 1-octanol, respectively. Under an applied potential of 250 V in the course of the extraction process, acidic, and basic drugs were extracted from a 3.0 mL aqueous sample solution into 25 μL acceptor solutions. The pH values of the donor and acceptor solutions in the cathodic cell were 5.0 and 1.5, respectively, the corresponding values in the anodic cell were, however, 8.0 and 12.5, respectively. The rates of recovery obtained within 20 min of extraction time at a stirring rate of 750 rpm ranged from 45 to 54%. With correlation coefficients ranging from 0.990 to 0.996, the proposed EME technique provided good linearity over a concentration range of 20-1000 ng/mL. The LOD for all drugs was found to be 6.7 ng/mL, while reproducibility ranged from 7 to 12% (n = 5). Finally, applying the proposed method to determine and quantify the drugs in urine and wastewater samples, satisfactory results were achieved.
从样品中同时提取酸性和碱性分析物是一项具有挑战性的任务。在这项工作中,一种基于两个独立单元的新型高效电膜萃取(EME)方法被用于同时提取和预富集两种酸性药物(萘普生和布洛芬)以及一种碱性药物(氯胺酮)。一旦两个单元都充满样品溶液,碱性药物从一个单元中被提取出来,而另一个单元用于提取酸性药物。用于提取酸性和碱性药物的支撑液膜分别为2-乙基己醇和1-辛醇。在萃取过程中施加250 V的电位,酸性和碱性药物从3.0 mL的水样溶液中被萃取到25 μL的接受液中。阴极单元中供体和接受液的pH值分别为5.0和1.5,然而,阳极单元中的相应值分别为8.0和12.5。在750 rpm的搅拌速率下,萃取20分钟内获得的回收率在45%至54%之间。所提出的EME技术的相关系数在0.990至0.996之间,在20 - 1000 ng/mL的浓度范围内具有良好的线性。所有药物的检测限为6.7 ng/mL,而重现性在7%至12%之间(n = 5)。最后,将所提出的方法应用于尿液和废水样品中药物的测定和定量,取得了满意的结果。