The aim of the study was to compare ultrasonography (US) and surface landmark techniques for detecting the cricothyroid membrane (CTM) to perform a cricothyroidotomy on healthy volunteers.
In this prospective observational study, 5 operators and 24 models were included. The borders of the CTM were marked with an invisible pen. The operators were asked to point the CTM either with the palpation method or the US-guided fashion.
The CTM was detected accurately in 80 (66.7%) attempts with palpation and 83 (69.2%) attempts with US. There was no statistically significant difference in the accuracy of detection of the CTM with palpation and US. The mean time for detecting the CTM with palpation was 8.25 ± 4.8 seconds (95% confidence interval, 7.3-9.1). The mean time for detecting CTM with US was 17 ± 9.2 seconds (95% confidence interval, 15.3-18.7). The duration for detecting the localization of the CTM was longer with US.
According to the results of this study, the accuracy of US and palpation was similar in detecting the localization of the CTM. However, the duration for detecting the CTM was longer with US when compared with the palpation technique.
本研究旨在比较超声检查(US)和体表标志技术在健康志愿者身上检测环甲膜(CTM)以实施环甲膜切开术的效果。
在这项前瞻性观察研究中,纳入了5名操作者和24名模型对象。用不可见笔标记环甲膜的边界。要求操作者通过触诊法或超声引导方式指出环甲膜的位置。
触诊法检测环甲膜的80次尝试(66.7%)和超声检测的83次尝试(69.2%)中,环甲膜均被准确检测到。触诊和超声检测环甲膜的准确性无统计学显著差异。触诊检测环甲膜的平均时间为8.25±4.8秒(95%置信区间,7.3 - 9.1)。超声检测环甲膜的平均时间为17±9.2秒(95%置信区间,15.3 - 18.7)。超声检测环甲膜定位的持续时间更长。
根据本研究结果,超声和触诊在检测环甲膜定位方面的准确性相似。然而,与触诊技术相比,超声检测环甲膜的持续时间更长。