Suppr超能文献

血液透析患者眼反应分析仪测量眼压的评估

Evaluation of Intraocular Pressure by Ocular Response Analyzer in Patients Undergoing Hemodialysis.

作者信息

Yuksel Nilay, Duru Necati, Uz Ebru, Mutlu Melek, Altinkaynak Hasan, Ozen Umut, Turkyilmaz Mustafa, Cagil Nurullah

机构信息

Departments of *Ophthalmology †Nephrology, Yildirim Beyazit University, Ankara Ataturk Education and Research Hospital, Ankara, Turkey.

出版信息

J Glaucoma. 2016 Apr;25(4):e355-8. doi: 10.1097/IJG.0000000000000364.

Abstract

PURPOSE

The aim of this study was to compare the biomechanical parameters of the cornea and intraocular pressure (IOP) before and after hemodialysis (HD) in patients with end-stage renal disease (ESRD) and also healthy subjects.

MATERIALS AND METHODS

Twenty-one patients with ESRD undergoing HD treatment (study group) and 21 healthy individuals (control group) were enrolled in this prospective study. Right eyes of each subjects were included. Central corneal thickness (CCT) were measured using Sirius Scheimpflug camera. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated IOP (IOPcc), and Goldmann-related IOP (IOPg) were measured using ocular response analyzer. In the study group, measurements were taken just before HD and 30 minutes after HD.

RESULTS

The mean CCT, CRF, IOPg values did not differ between pre-HD, post-HD, and controls (P > 0.05). CH was found to be significantly higher in control group (10.6 ± 1.2 mm Hg) when compared with pre-HD (8.07 ± 1.8 mm Hg) and post-HD (8.8 ± 1.6 mm Hg) CH values (P = 0.0001). The mean IOPcc values did not differ pre-HD (18.5 ± 3.5 mm Hg) and post-HD (17.8 ± 3.9 mm Hg) (P = 0.39). The mean IOPcc values were lower significantly in control group (15.4 ± 2.8 mm Hg) when compared with pre-HD and post-HD values (P = 0.02 and 0.02, respectively). Significant correlations were seen between post-HD CRF and post-HD CCT (r = 0.6, P = 0.03); and post-HD IOPg and post-HD CCT (r = 0.51, P = 0.01).

CONCLUSIONS

ESRD may disrupt the biomechanical properties of the cornea. Changes in ocular response analyzer parameters should be kept in mind to evaluate accurate IOP measurements in patients with ESRD.

摘要

目的

本研究旨在比较终末期肾病(ESRD)患者及健康受试者血液透析(HD)前后角膜生物力学参数和眼内压(IOP)。

材料与方法

本前瞻性研究纳入了21例接受HD治疗的ESRD患者(研究组)和21名健康个体(对照组)。纳入了每个受试者的右眼。使用Sirius Scheimpflug相机测量中央角膜厚度(CCT)。使用眼反应分析仪测量角膜滞后(CH)、角膜阻力因子(CRF)、角膜补偿眼压(IOPcc)和Goldmann相关眼压(IOPg)。在研究组中,在HD前和HD后30分钟进行测量。

结果

HD前、HD后及对照组之间的平均CCT、CRF、IOPg值无差异(P>0.05)。发现对照组的CH(10.6±1.2 mmHg)显著高于HD前(8.07±1.8 mmHg)和HD后(8.8±1.6 mmHg)的CH值(P = 0.0001)。HD前(18.5±3.5 mmHg)和HD后(17.8±3.9 mmHg)的平均IOPcc值无差异(P = 0.39)。与HD前和HD后的值相比,对照组的平均IOPcc值显著较低(15.4±2.8 mmHg)(分别为P = 0.02和0.02)。HD后CRF与HD后CCT之间存在显著相关性(r = 0.6,P = 0.03);HD后IOPg与HD后CCT之间也存在显著相关性(r = 0.51,P = 0.01)。

结论

ESRD可能会破坏角膜的生物力学特性。在评估ESRD患者的准确眼压测量时,应牢记眼反应分析仪参数的变化。