Suppr超能文献

消毒技术对添加或未添加色素的热聚甲基丙烯酸树脂弯曲强度的影响。

The Effect of Disinfection Techniques on the Flexural Strength of Thermopolymerisable Acrylic Resins With or Without Pigment Addition.

作者信息

Goiato Marcelo Coelho, Zuccolotti Bruna Carolina Rossatti, Haddad Marcela Filié, Moreno Amália, Pesqueira Aldiéris Alves, Gennari Humberto Filho, Dos Santos Daniela Micheline

出版信息

Eur J Prosthodont Restor Dent. 2015 Dec;23(4):193-8.

Abstract

OBJECTIVES

The aim of this study was to assess the flexural strength of two brands of thermopolymerisable acrylic resins (Onda Cryl, Artigos Odontológicos Clássico Ltda, São Paulo, SP, Brazil; and Lucitone 550, Dentsply, York, PA, USA) with varying concentrations of pigment (Poli-Côr, Artigos Odontológicos Clássico Ltda, São Paulo, SP, Brazil) under the influence of thermocycling, storage and disinfection.

MATERIAL AND METHODS

A total of 210 samples were manufactured (105 for each acrylic resin brand), with dimensions of 64 x 10 x 3.3 mm. The samples were divided into 30 subgroups (n = 7) according to the proportion of pigment used (without pigment, 3% and 7%), the assessment period (initial or thermocycling for 2000 cycles) and disinfection method (immersion in 1% sodium hypochlorite, (Apothicário, Araçatuba, SP, Brazil), microwave energy or immersion in alkaline peroxide (Efferdent, Pfizer, Morris Plains, NJ, USA). The samples were submitted to the flexural strength test before and after thermocycling, and after storage with disinfection. The disinfection process was performed every 3 days, for 60 days. Data were submitted to analysis of variance (ANOVA) and Tukey test (p < 0.05).

RESULTS

The factors that provided statistical alteration in flexural strength values were resin type and assessment period. The Onda Cryl resin and the period after disinfection (126 ± 25 MPa) exhibited the higher values of flexural strength.

CONCLUSION

Following disinfection, Onda-Cryl resin exhibited the highest values of flexural strength. All the samples obtained are considered clinically acceptable.

摘要

目的

本研究旨在评估两种品牌的热聚甲基丙烯酸树脂(Onda Cryl,巴西圣保罗Artigos Odontológicos Clássico Ltda公司;Lucitone 550,美国宾夕法尼亚州约克Dentsply公司)在热循环、储存和消毒影响下,不同浓度色素(巴西圣保罗Artigos Odontológicos Clássico Ltda公司的Poli-Côr)对其弯曲强度的影响。

材料与方法

共制作210个样本(每个丙烯酸树脂品牌105个),尺寸为64×10×3.3毫米。根据所用色素比例(无色素、3%和7%)、评估期(初始或热循环2000次)和消毒方法(浸泡于1%次氯酸钠(巴西阿拉萨图巴Apothicário公司)、微波能量或浸泡于碱性过氧化物(美国新泽西州莫里斯平Pfizer公司的Efferdent))将样本分为30个亚组(n = 7)。在热循环前后以及储存并消毒后对样本进行弯曲强度测试。消毒过程每3天进行一次,持续60天。数据进行方差分析(ANOVA)和Tukey检验(p < 0.05)。

结果

导致弯曲强度值出现统计学变化的因素为树脂类型和评估期。Onda Cryl树脂以及消毒后阶段(126±25兆帕)的弯曲强度值较高。

结论

消毒后,Onda-Cryl树脂的弯曲强度值最高。所有获得的样本在临床上均被认为是可接受的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验