Astigmatic Peripheral Defocus with Different Contact Lenses: Review and Meta-Analysis.

作者信息

Queirós António, Lopes-Ferreira Daniela, González-Méijome José Manuel

机构信息

a Clinical & Experimental Optometry Research Lab, Center of Physics , University of Minho , Braga , Portugal.

出版信息

Curr Eye Res. 2016 Aug;41(8):1005-1015. doi: 10.3109/02713683.2015.1116585. Epub 2016 Feb 2.

Abstract

PURPOSE

To review the level of relative peripheral defocus measured with different devices with potential use for myopia retention. To present comparative data of the change in astigmatic peripheral refraction with different contact lenses evaluated in different studies conducted in the same laboratory following the same methodology in myopic human eyes Methods: A joint analysis of work, carried out at the same laboratory (CEORLab) in 137 myopic subjects with different types of contact lenses (CL), was performed to obtain the tangential (F = M - J0), sagittal (F = M + J0), and mean (M) power refractive errors (M and J0 are the refraction vector components). Orthokeratology, standard aspheric rigid gas-permeable (RGP), experimental RGP, experimental soft CL, and different multifocal soft CL were used to induce peripheral myopic defocus (236 peripheral refraction measures).

RESULTS

Compared with values obtained in naked eye condition (baseline), only three of the eight approaches tested show statistically significant peripheral myopic defocus induction (p < 0.001) in both temporal and nasal retina (orthokeratology, experimental RGP, and Proclear multifocal CL with Add: +3.00 D). Standard aspheric RGP also produced a significant increase in myopic defocus for the F, of about -2.00 D. The experimental soft CL, designed to mimic the peripheral performance of the experimental RGP, induced a similar effect to the standard aspheric soft CL.

CONCLUSION

Orthokeratology, multifocal soft CL, and custom-designed RGP CL were able to generate a significant relative peripheral myopia in myopic eyes. Conversely, standard and experimental soft CL were not able to induce significant peripheral myopic and astigmatic defocus values.

摘要

目的

回顾使用不同设备测量的相对周边离焦水平,这些设备可能用于近视控制。展示在同一实验室按照相同方法对近视人眼进行的不同研究中,不同隐形眼镜引起的散光周边屈光变化的比较数据。方法:对在同一实验室(CEORLab)对137名近视受试者使用不同类型隐形眼镜(CL)所做的工作进行联合分析,以获得切向(F = M - J0)、矢状(F = M + J0)和平均(M)屈光不正度数(M和J0是屈光向量分量)。使用角膜塑形术、标准非球面硬性透气性(RGP)、实验性RGP、实验性软性CL和不同的多焦点软性CL来诱导周边近视性离焦(236次周边屈光测量)。

结果

与裸眼条件(基线)下获得的值相比,测试的八种方法中只有三种在颞侧和鼻侧视网膜均显示出统计学上显著的周边近视性离焦诱导(p < 0.001)(角膜塑形术、实验性RGP和附加度数为+3.00 D的博士伦多焦点CL)。标准非球面RGP在F值上也产生了约-2.00 D的近视性离焦显著增加。旨在模拟实验性RGP周边性能的实验性软性CL诱导出与标准非球面软性CL相似的效果。

结论

角膜塑形术、多焦点软性CL和定制设计的RGP CL能够在近视眼中产生显著的相对周边近视。相反,标准和实验性软性CL不能诱导出显著的周边近视性和散光性离焦值。