Suppr超能文献

相似文献

1
Current practices in corrosion, surface characterization, and nickel leach testing of cardiovascular metallic implants.
J Biomed Mater Res B Appl Biomater. 2017 Aug;105(6):1330-1341. doi: 10.1002/jbm.b.33630. Epub 2016 Feb 16.
2
The effect of fatigue on the corrosion resistance of common medical alloys.
J Biomed Mater Res B Appl Biomater. 2017 Oct;105(7):2019-2026. doi: 10.1002/jbm.b.33738. Epub 2016 Jul 4.
3
Effect of wire fretting on the corrosion resistance of common medical alloys.
J Biomed Mater Res B Appl Biomater. 2017 Nov;105(8):2487-2494. doi: 10.1002/jbm.b.33788. Epub 2016 Sep 23.
4
The use of electrochemical techniques to evaluate the corrosion performance of metallic biomedical materials and devices.
J Biomed Mater Res B Appl Biomater. 2019 May;107(4):1189-1198. doi: 10.1002/jbm.b.34212. Epub 2018 Sep 5.
5
The effects of surface processing on in-vivo corrosion of Nitinol stents in a porcine model.
Acta Biomater. 2017 Oct 15;62:385-396. doi: 10.1016/j.actbio.2017.08.029. Epub 2017 Aug 24.
6
In Vitro Corrosion Assessment of the Essure® Medical Device in Saline, Simulated Inflammatory Solution and Neutral Buffered Formalin.
Acta Biomater. 2022 Jul 15;147:414-426. doi: 10.1016/j.actbio.2022.05.028. Epub 2022 May 19.
8
Corrosion resistance of a Nitinol ocular microstent: Implications on biocompatibility.
J Biomed Mater Res B Appl Biomater. 2020 Aug;108(6):2681-2690. doi: 10.1002/jbm.b.34599. Epub 2020 Mar 11.
9
Clinical relevance of corrosion patterns attributed to inflammatory cell-induced corrosion: A retrieval study.
J Biomed Mater Res B Appl Biomater. 2017 Jan;105(1):155-164. doi: 10.1002/jbm.b.33540. Epub 2015 Oct 6.
10
Phosphate conversion coating reduces the degradation rate and suppresses side effects of metallic magnesium implants in an animal model.
J Biomed Mater Res B Appl Biomater. 2017 Aug;105(6):1622-1635. doi: 10.1002/jbm.b.33704. Epub 2016 May 6.

引用本文的文献

1
A Predictive Toxicokinetic Model for Nickel Leaching from Vascular Stents.
ACS Biomater Sci Eng. 2024 Apr 8;10(4):2534-2551. doi: 10.1021/acsbiomaterials.3c01436. Epub 2024 Mar 25.
3
Nitinol Release of Nickel under Physiological Conditions: Effects of Surface Oxide, pH, Hydrogen Peroxide, and Sodium Hypochlorite.
Shap Mem Superelasticity. 2022 Jun;8:98-106. doi: 10.1007/s40830-022-00364-3. Epub 2022 Apr 28.
4
Reversible and multiphasic parenchymal changes in MRI after coil embolization for a ruptured cerebral aneurysm.
Surg Neurol Int. 2023 Apr 21;14:147. doi: 10.25259/SNI_160_2023. eCollection 2023.
5
Temperature dependence of nickel ion release from nitinol medical devices.
J Biomed Mater Res B Appl Biomater. 2021 Aug;109(8):1188-1197. doi: 10.1002/jbm.b.34781. Epub 2020 Dec 19.
6
On the High Sensitivity of Corrosion Resistance of NiTi Stents with Respect to Inclusions: An Experimental Evidence.
ACS Omega. 2020 Feb 10;5(6):3073-3079. doi: 10.1021/acsomega.9b04312. eCollection 2020 Feb 18.
7
Extracellular Matrix Bioscaffolds as Immunomodulatory Biomaterials<sup/>.
Tissue Eng Part A. 2017 Oct;23(19-20):1152-1159. doi: 10.1089/ten.TEA.2016.0538. Epub 2017 May 19.
8
The effect of fatigue on the corrosion resistance of common medical alloys.
J Biomed Mater Res B Appl Biomater. 2017 Oct;105(7):2019-2026. doi: 10.1002/jbm.b.33738. Epub 2016 Jul 4.

本文引用的文献

1
Superficial femoral artery nitinol stent in a patient with nickel allergy.
J Vasc Surg. 2013 Nov;58(5):1388-90. doi: 10.1016/j.jvs.2013.01.041. Epub 2013 Apr 20.
2
Arsenic, metals, fibres, and dusts.
IARC Monogr Eval Carcinog Risks Hum. 2012;100(Pt C):11-465.
3
Outcomes after coronary stent implantation in patients with metal allergy.
Circ Cardiovasc Interv. 2012 Apr;5(2):220-6. doi: 10.1161/CIRCINTERVENTIONS.111.966614. Epub 2012 Mar 27.
5
Clinical device-related article surface characterization of explanted endovascular stents: evidence of in vivo corrosion.
J Biomed Mater Res B Appl Biomater. 2010 Oct;95(1):225-38. doi: 10.1002/jbm.b.31698.
6
Electrochemical behavior of cobalt-chromium alloys in a simulated physiological solution.
J Biomed Mater Res A. 2010 Jul;94(1):93-102. doi: 10.1002/jbm.a.32684.
7
Metal allergy to Amplatzer occluder device presented as severe bronchospasm.
Ann Thorac Surg. 2009 Dec;88(6):2021-2. doi: 10.1016/j.athoracsur.2009.05.044.
8
Drug-eluting stent thrombosis: the Kounis hypersensitivity-associated acute coronary syndrome revisited.
JACC Cardiovasc Interv. 2009 Jul;2(7):583-93. doi: 10.1016/j.jcin.2009.04.017.