A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements.

作者信息

Meislin Megan A, Wagner Eric R, Shin Alexander Y

机构信息

Department of Orthopedic Surgery, Division of Hand Surgery, Mayo Clinic, Rochester, MN.

Department of Orthopedic Surgery, Division of Hand Surgery, Mayo Clinic, Rochester, MN.

出版信息

J Hand Surg Am. 2016 Apr;41(4):510-515.e1. doi: 10.1016/j.jhsa.2016.01.006. Epub 2016 Feb 13.

Abstract

PURPOSE

The purpose of this study was to validate elbow flexion and extension measured from smartphone photography obtained by participants and compared them with photographs obtained by surgeons and goniometric measurements.

METHODS

We enrolled 32 participants with a total of 64 elbows, aged 25 to 68 years. Participants obtained smartphone photographs of full elbow flexion and extension. Then surgeons obtained the same photographs and goniometric measurement of elbow range of motion (ROM). We measured ROM from the photographs using Adobe Photoshop and calculated average ROM. Comparisons of manual goniometer versus digital measurements, participant versus surgeon photograph measurements, and interobserver measurements were statistically analyzed.

RESULTS

Average ROM measured by manual goniometer and digital photographs was 0° to 129° (range, 0° to 140°) and 0° to 129° (range, 0° to 145°), respectively. The goniometer versus digital measurements interclass correlation was 0.828 (L) and 0.740 (R). Pearson coefficient was 0.845 (L) and 0.757 (R). Bland-Altman plots demonstrated that 30 of 32 digital measurements (L) and 31 of 32 measurements (R) were within the 95% confidence interval. Participant-obtained photographs compared with researcher's photographs interclass correlation was 0.955 (L) and 0.941 (R), with a Pearson coefficient of 0.962 (L) and 0.957 (R), respectively. Reviewing interobserver reliability, concordance coefficients were 0.793 (L) and 0.767 (R) and Pearson coefficients were 0.811 (L) and 0.780 (R). Bland-Altman plots demonstrated that 28 of 32 digital measurements (L) and 26 of 32 measurements (R) were within the 95% confidence interval.

CONCLUSIONS

Measuring elbow ROM using smartphone digital photography is valid and reliable. Participants were able to obtain accurate photographs and the measurements based on these photographs show no statistical difference from those taken by surgeons or goniometric measurement.

CLINICAL RELEVANCE

This study validates using smartphone photography for measuring elbow ROM by laymen in a remote setting.

TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.

摘要

目的

本研究旨在验证参与者通过智能手机拍摄的照片所测量的肘部屈伸情况,并将其与外科医生拍摄的照片及角度测量结果进行比较。

方法

我们招募了32名参与者,共64个肘部,年龄在25至68岁之间。参与者拍摄肘部完全屈伸的智能手机照片。然后外科医生拍摄相同的照片并进行肘部活动范围(ROM)的角度测量。我们使用Adobe Photoshop从照片中测量ROM并计算平均ROM。对手动角度计与数字测量、参与者与外科医生照片测量以及观察者间测量进行统计学分析。

结果

手动角度计和数字照片测量的平均ROM分别为0°至129°(范围,0°至140°)和0°至129°(范围,0°至145°)。角度计与数字测量的组内相关系数左侧为0.828,右侧为0.740。皮尔逊系数左侧为0.845,右侧为0.757。布兰德 - 奥特曼图显示,32次数字测量中的30次(左侧)和32次测量中的31次(右侧)在95%置信区间内。参与者拍摄的照片与研究人员拍摄的照片的组内相关系数左侧为0.955,右侧为0.941,皮尔逊系数分别为0.962(左侧)和0.957(右侧)。观察观察者间可靠性时,一致性系数左侧为0.793,右侧为0.767,皮尔逊系数左侧为0.811,右侧为0.780。布兰德 - 奥特曼图显示,32次数字测量中的28次(左侧)和32次测量中的26次(右侧)在95%置信区间内。

结论

使用智能手机数字摄影测量肘部ROM是有效且可靠的。参与者能够获得准确的照片,基于这些照片的测量结果与外科医生拍摄的照片或角度测量结果无统计学差异。

临床相关性

本研究验证了在远程环境中由外行人使用智能手机摄影测量肘部ROM的方法。

研究类型/证据水平:诊断性II级。