Suppr超能文献

腕关节活动范围的远程评估:提供者估计与通过照片和描记法进行直接测量的观察者间和观察者内一致性

Remote Assessment of Wrist Range of Motion: Inter- and Intra-Observer Agreement of Provider Estimation and Direct Measurement With Photographs and Tracings.

作者信息

Scott Kelly L, Skotak Cecelia M, Renfree Kevin J

机构信息

Department of Orthopaedic Surgery, Mayo Clinic Arizona, Phoenix, AZ.

Department of Physical Medicine and Rehabilitation, Mayo Clinic Arizona, Phoenix, AZ.

出版信息

J Hand Surg Am. 2019 Nov;44(11):954-965. doi: 10.1016/j.jhsa.2019.05.017. Epub 2019 Jul 26.

Abstract

PURPOSE

Information is limited regarding the validity and reliability of measurements made during remote assessment of wrist range of motion (ROM) motion. We sought to determine intra- and inter-observer agreement among visual estimation, direct goniometric measurement, and patients' self-taken digital photographs and line tracings by comparing the degree differences among measurements. We hypothesized that inter- and intra-observer differences would be less than 10° at least 90% of the time for all measurement modalities.

METHODS

Thirty-seven patients were enrolled in this prospective cohort study. Visual estimation immediately followed by direct goniometry of maximal active wrist ROM (extension [E], flexion [F], radial deviation, and ulnar deviation) were independently and blindly assessed by 3 different providers: a hand surgeon, a hand therapist, and an orthopedic resident. Self-taken photographs and line tracings were blindly evaluated 3 weeks later. Intra- and inter-observer agreement was described using the Bland-Altman method.

RESULTS

The surgeon and hand therapist observed intra-observer agreement within 10° for visual estimation of all 4 directions of motions greater than 90% of the time, but inter-observer agreement for E/F was lower (76% to 86%). Intra-observer agreement by the resident was within 10° 78% of the time for E/F. Intra-observer agreement for photographs and tracings were lower than visual estimation for all observers. Inter-observer agreement for photographs and tracings was higher than intra-observer agreement. The surgeon and hand therapist agreed within 10° at least 76% of the time, the surgeon and resident agreed within 10° at least 62% of the time, and the hand therapist and resident agreed within 10° at least 54% of the time.

CONCLUSIONS

Visual estimation may be a valid method of remote assessment, but compared with goniometry, measurements may be susceptible to observer bias. Self-taken photographs and line tracings are unreliable, perhaps falsely lower owing to submaximal effort from task distraction, and we question their current use for remote assessment of wrist ROM.

CLINICAL RELEVANCE

These results represent an initial step in evaluating potential methods of remote assessment of wrist ROM.

摘要

目的

关于腕关节活动范围(ROM)远程评估期间测量的有效性和可靠性的信息有限。我们试图通过比较测量之间的度数差异,来确定视觉估计、直接测角测量以及患者自行拍摄的数码照片和线条描记法之间的观察者内和观察者间一致性。我们假设,对于所有测量方式,观察者间和观察者内差异在至少90%的时间内小于10°。

方法

37名患者纳入了这项前瞻性队列研究。由3名不同的医疗人员独立且盲法评估最大主动腕关节ROM(伸展[E]、屈曲[F]、桡偏和尺偏),先进行视觉估计,随后立即进行直接测角法,这3名人员分别是一名手外科医生、一名手部治疗师和一名骨科住院医师。3周后对患者自行拍摄的照片和线条描记法进行盲法评估。使用Bland-Altman方法描述观察者内和观察者间一致性。

结果

外科医生和手部治疗师在超过90% 的时间里,对于所有4个运动方向的视觉估计,观察者内一致性在10°以内,但E/F的观察者间一致性较低(76%至86%)。住院医师对于E/F的观察者内一致性在78%的时间内处于10°以内。对于所有观察者,照片和描记法的观察者内一致性低于视觉估计。照片和描记法的观察者间一致性高于观察者内一致性。外科医生和手部治疗师在至少7*6%*的时间内一致性在10°以内,外科医生和住院医师在至少62%的时间内一致性在10°以内,手部治疗师和住院医师在至少54%的时间内一致性在10°以内。

结论

视觉估计可能是一种有效的远程评估方法,但与测角法相比,测量结果可能易受观察者偏差影响。患者自行拍摄的照片和线条描记法不可靠,可能由于任务分心导致用力不足而被错误低估,我们质疑它们目前在腕关节ROM远程评估中的应用。

临床意义

这些结果代表了评估腕关节ROM远程评估潜在方法的第一步。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验