Radiographic evaluation of short-stem press-fit total shoulder arthroplasty: short-term follow-up.

作者信息

Casagrande Danielle J, Parks Di L, Torngren Travis, Schrumpf Mark A, Harmsen Samuel M, Norris Tom R, Kelly James D

机构信息

San Francisco Shoulder, Elbow, and Hand Clinic, San Francisco, CA, USA.

San Francisco Shoulder, Elbow, and Hand Clinic, San Francisco, CA, USA.

出版信息

J Shoulder Elbow Surg. 2016 Jul;25(7):1163-9. doi: 10.1016/j.jse.2015.11.067. Epub 2016 Feb 17.

Abstract

BACKGROUND

Humeral loosening is an uncommon etiology for revision shoulder arthroplasty. We aimed to evaluate the radiographic and clinical outcomes of a short-stem press-fit humeral component after primary total shoulder arthroplasty.

METHODS

We reviewed our patient database, from January 2008 to December 2011, for primary total shoulder arthroplasties performed with a short-stem press-fit humeral component. Radiographs and clinical outcomes were evaluated in the immediate postoperative period and at the most recent follow-up, with at least 24 months of data for all patients.

RESULTS

There were 73 shoulders that met our inclusion criteria, but 4 underwent revision before 2 years' follow-up. Only 1 of these 4 was revised for aseptic humeral loosening. Sixty-nine shoulders had at least 24 months of radiographic follow-up, and 62 had radiographic and clinical follow-up. Of the 69 shoulders, 5 underwent revision for humeral loosening: 1 for aseptic loosening and 4 for infection. Two other shoulders with humeral loosening were asymptomatic, and the patients refused revision surgery. The overall revision rate for humeral loosening was 8.2% (6 of 73 shoulders). Radiolucent zones of any size were seen in 71.0%, with 8.7% of these shoulders identified as having humeral stems at risk of future loosening. Significant improvements were made in most of the measured clinical outcomes.

CONCLUSIONS

A high percentage of radiolucency was seen around the short-stem press-fit humeral components evaluated in this study at short-term follow-up. The overall rates of loosening and revision for the humeral implant examined in this study are higher than those noted in other recent studies evaluating press-fit stems. The cause of radiolucency and humeral loosening for this implant is not fully understood.

摘要

背景

肱骨松动是翻修肩关节置换术的一种不常见病因。我们旨在评估初次全肩关节置换术后短柄压配型肱骨假体的影像学和临床结果。

方法

我们回顾了2008年1月至2011年12月期间使用短柄压配型肱骨假体进行初次全肩关节置换术的患者数据库。在术后即刻和最近一次随访时评估影像学和临床结果,所有患者至少有24个月的数据。

结果

有73例肩关节符合我们的纳入标准,但4例在2年随访前进行了翻修。这4例中只有1例因无菌性肱骨松动进行了翻修。69例肩关节有至少24个月的影像学随访,62例有影像学和临床随访。在这69例肩关节中,5例因肱骨松动进行了翻修:1例为无菌性松动,4例为感染。另外2例肱骨松动的肩关节无症状,患者拒绝翻修手术。肱骨松动的总体翻修率为8.2%(73例肩关节中的6例)。71.0%的患者出现了任何大小的透亮区,其中8.7%的肩关节被确定为肱骨柄有未来松动的风险。大多数测量的临床结果有显著改善。

结论

在本研究的短期随访中,在评估的短柄压配型肱骨假体周围发现了高比例的透亮区。本研究中检查的肱骨植入物的松动和翻修总体发生率高于其他近期评估压配型柄的研究中所指出的发生率。这种植入物的透亮区和肱骨松动的原因尚未完全了解。