Nakazawa Katsumasa, Manaka Tomoya, Hirakawa Yoshihiro, Ito Yoichi, Iio Ryosuke, Oi Naoki, Nakamura Hiroaki
Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Ishikiriseiki hospital, Higashiosaka, Japan.
JSES Int. 2023 Sep 22;8(1):119-125. doi: 10.1016/j.jseint.2023.08.015. eCollection 2024 Jan.
There are numerous reports of bone adaptation observed on plain radiography studies after the use of cementless short stems in reverse shoulder arthroplasty. However, reports on changes in bone mineral density (BMD) around the stem using dual-energy X-ray absorptiometry (DEXA) are prominently absent. In the present study, we measured BMD around the stem using DEXA and investigated changes over time from postoperative year 1 to year 2. Additionally, the relationship between BMD changes, filling ratio, and stem alignment was examined.
Forty-seven patients with short cementless stems who could be assessed via DEXA at 1-2 years postoperatively were included. After dividing the zones around the stem into 5, the BMD in each zone was measured, in addition to BMD changes and amount of change from postoperative year 1 to year 2. The relationship between filling ratio and stem alignment on postoperative plain radiography was assessed.
A significant decrease in BMD in zone 3 was observed between postoperative year 1 and year 2 ( = .02). Regarding filling ratio and stem alignment, a negative correlation between valgus stem alignment and BMD change observed in zone 1 (r = -0.470, < .01). In addition, stem valgus greater than 6° correlated with a significant decrease in BMD in zone 1. ( = .01). No significant differences were found in the other zones. Furthermore, there was no correlation between filling ratio and BMD change.
In reverse shoulder arthroplasty cementless short stems, changes that that occurred between postoperative year 1 to year 2 demonstrated a decrease in BMD in zone 3. In addition, a decrease in BMD in zone 1 was observed with a stem alignment of valgus 6° or higher, suggesting that stem alignment within valgus 6° is required to prevent a decrease in BMD.
在使用非骨水泥短柄进行反式肩关节置换术后的X线平片研究中,有大量关于骨适应性的报道。然而,使用双能X线吸收法(DEXA)测量柄周围骨密度(BMD)变化的报道却明显缺乏。在本研究中,我们使用DEXA测量柄周围的BMD,并调查术后第1年到第2年随时间的变化。此外,还研究了BMD变化、填充率和柄对线之间的关系。
纳入47例使用非骨水泥短柄且术后1至2年可通过DEXA评估的患者。将柄周围区域分为5个区后,测量每个区的BMD,以及术后第1年到第2年的BMD变化和变化量。评估术后X线平片上的填充率和柄对线之间的关系。
术后第1年和第2年之间,观察到3区的BMD显著下降(P = 0.02)。关于填充率和柄对线,在1区观察到外翻柄对线与BMD变化之间呈负相关(r = -0.470,P < 0.01)。此外,柄外翻大于6°与1区BMD显著下降相关(P = 0.01)。其他区未发现显著差异。此外,填充率与BMD变化之间无相关性。
在反式肩关节置换术中使用非骨水泥短柄时,术后第1年到第2年发生的变化显示3区BMD下降。此外,当柄外翻对线为6°或更高时,观察到1区BMD下降,这表明需要将柄外翻对线控制在6°以内以防止BMD下降。