a Department of Orthopaedics and Traumatology .
b Department of Pathology , Kantonsspital St. Gallen , Switzerland.
Acta Orthop. 2016 Jun;87(3):239-44. doi: 10.3109/17453674.2016.1152853. Epub 2016 Feb 24.
Background and purpose - Biodegradable cement restrictors are widely used in hip arthroplasty. Like others, we observed osteolytic reactions associated with a specific cement restrictor (SynPlug; made of PolyActive) and reviewed our patients. Patients and methods - We identified 703 patients with suitable radiographs from our database (2007 to 2012) who underwent cemented hip arthroplasty and received a SynPlug biodegradable cement restrictor. We reviewed all available radiographs to determine the incidence, severity, and progression of osteolysis. Mean postoperative follow-up was 1.8 (1-7) years Results - 1 year after implantation, the femoral cortex showed thinning by 12% in the anterior-posterior view and by 8% in the axial view. This had increased to 14% and 12%, respectively, at the latest available follow-up postoperatively (at a mean of 4 years). Cortical thinning of less than 10% was found in 37% of patients, but cortical thinning of 10-30% was found in 56% of patients. In the remaining 7%, a reduction of more than 30% of the original cortical thickness was observed. Interpretation - Osteolytic changes associated with the SynPlug biodegradable bone restrictors are inconsistent and highly variable. While some patients showed increased weakening of the femoral cortex with the potential risk of periprosthetic fracture, in others the degree of osteolysis only increased slightly or stabilized after 2 or more years. Any cortical bone loss after total hip replacement should be avoided, so the use of PolyActive biodegradable cement restrictors should be discontinued. Patients with a PolyActive cement restrictor in place should be followed up closely after surgery.
背景与目的 - 可生物降解的水泥限制器在髋关节置换术中被广泛应用。与其他限制器一样,我们观察到与特定水泥限制器(SynPlug;由 PolyActive 制成)相关的溶骨性反应,并对我们的患者进行了回顾。
患者与方法 - 我们从数据库中(2007 年至 2012 年)确定了 703 名具有合适 X 光片的患者,他们接受了骨水泥髋关节置换术并接受了 SynPlug 可生物降解水泥限制器。我们回顾了所有可用的 X 光片,以确定溶骨的发生率、严重程度和进展情况。平均术后随访时间为 1.8(1-7)年。
结果 - 植入后 1 年,前后位股骨皮质变薄 12%,轴向位变薄 8%。在术后最近一次随访(平均 4 年)时,这一比例分别增加到 14%和 12%。37%的患者皮质变薄小于 10%,56%的患者皮质变薄 10-30%。在其余 7%的患者中,观察到原始皮质厚度减少超过 30%。
结论 - 与 SynPlug 可生物降解骨限制器相关的溶骨性变化不一致且高度可变。虽然一些患者出现股骨皮质的削弱增加,存在假体周围骨折的潜在风险,但在其他患者中,溶骨程度仅在 2 年或更长时间后略有增加或稳定。全髋关节置换术后任何皮质骨丢失都应避免,因此应停止使用 PolyActive 可生物降解水泥限制器。已经放置 PolyActive 水泥限制器的患者应在手术后密切随访。