Cohen Omer, Ormianer Zeev, Tal Haim, Rothamel Daniel, Weinreb Miron, Moses Ofer
Department of Periodontology and Dental Implantology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.
Department of Oral Rehabilitation, School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.
Clin Oral Investig. 2016 Dec;20(9):2475-2480. doi: 10.1007/s00784-016-1765-8. Epub 2016 Mar 2.
The objective of this study is to compare bone-to-implant contact (BIC) between implants inserted at high torque due to under-drilling of the crestal bone to those inserted at low torque due to over-drilling of the crestal bone.
Forty implants with diameters of 3.75 mm (group A) or 3.55 mm (group B) were inserted in the proximal tibiae of NZW rabbits in two separate surgeries on day 0 or 21. Osteotomy of the crestal bone was finalized with a 3.65-mm drill. In group A, implants were inserted at torque ≥35 Ncm (under-drilling) and in group B with torque <10 Ncm (over-drilling). Implants and their surrounding bone were retrieved on day 42, thus creating 3- and 6-week observation periods, processed for non-decalcified histology and stained with toluidine blue. Crestal BIC (c-BIC) and total BIC (t-BIC) were measured. Wilcoxon test was used to evaluate differences between groups.
Three weeks post-surgery, the mean c-BIC in group A was 16.3 ± 3.3 vs 31.5 ± 3.4 % in group B (P < 0.05). At 6 weeks, a similar trend was observed (group A: 28.7 ± 3.6 %; group B: 38.4 ± 4.9 %) (P > 0.05). No differences in t-BIC were noted at 3 weeks and at 6 weeks between the groups.
Insertion of implants with an over-drilling protocol of the crestal aspect of the osteotomy resulted in increased short-term crestal bone-to-implant contact.
Insertion of implants with a high torque following an under-drilling protocol, commonly used for immediate loading, may reduce crestal bone-to-implant contact at early healing stages.
本研究的目的是比较因嵴顶骨钻孔不足而高扭矩植入的种植体与因嵴顶骨钻孔过度而低扭矩植入的种植体之间的骨-种植体接触(BIC)情况。
40枚直径为3.75mm(A组)或3.55mm(B组)的种植体,于第0天或第21天在两个独立的手术中植入新西兰白兔的近端胫骨。用3.65mm的钻头完成嵴顶骨截骨术。A组种植体以≥35Ncm的扭矩植入(钻孔不足),B组种植体以<10Ncm的扭矩植入(钻孔过度)。在第42天取出种植体及其周围的骨组织,从而形成3周和6周的观察期,进行非脱钙组织学处理并用甲苯胺蓝染色。测量嵴顶BIC(c-BIC)和总BIC(t-BIC)。采用Wilcoxon检验评估组间差异。
术后3周,A组的平均c-BIC为16.3±3.3%,而B组为31.5±3.4%(P<0.05)。在6周时,观察到类似趋势(A组:28.7±3.6%;B组:38.4±4.9%)(P>0.05)。两组在3周和6周时的t-BIC均无差异。
采用截骨嵴顶方面的钻孔过度方案植入种植体可增加短期嵴顶骨-种植体接触。
按照常用于即刻负重的钻孔不足方案高扭矩植入种植体,可能会在早期愈合阶段减少嵴顶骨-种植体接触。