Lee Dong-Won, Choi Young-Shill, Park Kwang-Ho, Kim Chang-Sung, Moon Ik-Sang
Department of Periodontology, Yongdong Severance Hospital, College of Dentistry, Yonsei University, Seoul, Korea.
Clin Oral Implants Res. 2007 Aug;18(4):465-70. doi: 10.1111/j.1600-0501.2007.01302.x. Epub 2007 Apr 18.
The purpose of the present study was to evaluate the long-term effect of the microthread on the maintenance of marginal bone level.
Seventeen patients were selected and two types of Astra Tech implants were installed, with the Microthread on the coronal portion of the fixture [Astra Tech Single Tooth Implant (ST)] or without the Microthread [Astra Tech TiOblast Implant (TB)]. ST and TB were installed adjacent to each other within the same partially edentulous sites and marginal bone loss was evaluated by radiographic image. The marginal bone-level alteration of the each fixture after prosthesis insertion was analyzed.
The marginal bone loss of ST and TB differed significantly during the observation period (P<0.01). Marginal bone levels of both ST and TB were stabilized after 1 year of lading.
The Microthread might have an effect in maintaining the marginal bone loss against loading.