Abstract

OBJECTIVE

To investigate the cytotoxicity of nickel-titanium (NiTi) esthetic orthodontic archwires with different surface coatings.

MATERIALS AND METHODS

Three fully coated, tooth-colored NiTi wires (BioCosmetic, Titanol Cosmetic, EverWhite), two ion-implanted wires (TMA Purple, Sentalloy High Aesthetic), five uncoated NiTi wires (BioStarter, BioTorque, Titanol Superelastic, Memory Wire Superelastic, and Sentalloy), one β-titanium wire (TMA), and one stainless steel wire (Stainless Steel) were considered for this study. The wire samples were placed at 37°C in airtight test tubes containing Dulbecco's Modified Eagle's Medium (0.1 mg/mL) for 1, 7, 14, and 30 days. The cell viability of human gingival fibroblasts (HGFs) cultured with this medium was assessed by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. Data were analyzed by a two-way analysis of variance (α  =  .05).

RESULTS

The highest cytotoxic effect was reached on day 30 for all samples. The archwires exhibited a cytotoxicity on HGFs ranging from "none" to "slight," with the exception of the BioTorque, which resulted in moderate cytotoxicity on day 30. Significant differences were found between esthetic archwires and their uncoated pairs only for BioCosmetic (P  =  .001) and EverWhite (P < .001).

CONCLUSIONS

Under the experimental conditions, all of the NiTi esthetic archwires resulted in slight cytotoxicity, as did the respective uncoated wires. For this reason their clinical use may be considered to have similar risks to the uncoated archwires.

摘要

目的

研究不同表面涂层的镍钛(NiTi)美观正畸弓丝的细胞毒性。

材料与方法

本研究纳入三根全涂层、牙齿颜色的NiTi丝(BioCosmetic、Titanol Cosmetic、EverWhite)、两根离子注入丝(TMA Purple、Sentalloy High Aesthetic)、五根未涂层NiTi丝(BioStarter、BioTorque、Titanol Superelastic、Memory Wire Superelastic和Sentalloy)、一根β钛丝(TMA)和一根不锈钢丝(不锈钢)。将丝样置于37°C的气密试管中,试管中含有杜尔贝科改良伊格尔培养基(0.1 mg/mL),分别放置1、7、14和30天。采用3-(4,5-二甲基噻唑-2-基)-2,5-二苯基四氮唑溴盐(MTT)法评估用该培养基培养的人牙龈成纤维细胞(HGFs)的细胞活力。数据采用双向方差分析(α = 0.05)进行分析。

结果

所有样品在第30天达到最高细胞毒性作用。弓丝对HGFs的细胞毒性范围为“无”至“轻微”,BioTorque除外,其在第30天导致中度细胞毒性。仅BioCosmetic(P = 0.001)和EverWhite(P < 0.001)的美观弓丝与其未涂层配对之间存在显著差异。

结论

在实验条件下,所有NiTi美观弓丝以及相应的未涂层弓丝均导致轻微细胞毒性。因此,它们的临床应用可能被认为与未涂层弓丝具有相似的风险。

相似文献

1
In vitro biocompatibility of nickel-titanium esthetic orthodontic archwires.
Angle Orthod. 2016 Sep;86(5):789-95. doi: 10.2319/100415-663.1. Epub 2016 Mar 4.
2
Effects of intraoral aging on surface properties of coated nickel-titanium archwires.
Angle Orthod. 2014 Jul;84(4):665-72. doi: 10.2319/081213-593.1. Epub 2013 Dec 5.
3
A comparison of roughness parameters and friction coefficients of aesthetic archwires.
Eur J Orthod. 2015 Feb;37(1):49-55. doi: 10.1093/ejo/cju004. Epub 2014 Aug 1.
5
In vitro sliding-driven morphological changes in representative esthetic NiTi archwire surfaces.
Microsc Res Tech. 2015 Oct;78(10):926-34. doi: 10.1002/jemt.22557. Epub 2015 Aug 17.
7
Effect of gastric acids on surface topography and bending properties of esthetic coated nickel-titanium orthodontic archwires.
Clin Oral Investig. 2021 Mar;25(3):1319-1326. doi: 10.1007/s00784-020-03438-7. Epub 2020 Jul 3.
8
Deflection and Flexural Strength Effects on the Roughness of Aesthetic-Coated Orthodontic Wires.
Braz Dent J. 2017 Jan-Feb;28(1):40-45. doi: 10.1590/0103-6440201700630.
9
Attractiveness of different esthetic orthodontic wires.
Dental Press J Orthod. 2020 Nov-Dec;25(6):27-32. doi: 10.1590/2177-6709.25.6.027-032.oar.
10
Do laypersons perceive aesthetic differences between coated and uncoated orthodontic archwires?
Dental Press J Orthod. 2019 Jan-Feb;24(1):62-67. doi: 10.1590/2177-6709.24.1.062-067.oar.

引用本文的文献

1
Cytotoxicity and genotoxicity of orthodontic bands after aging: an in-vitro study.
BMC Oral Health. 2025 Jan 30;25(1):163. doi: 10.1186/s12903-025-05518-0.
3
In vitro wearing away of orthodontic brackets and wires in different conditions: A review.
Heliyon. 2022 Sep 7;8(9):e10560. doi: 10.1016/j.heliyon.2022.e10560. eCollection 2022 Sep.
4
Cytotoxicity effect of orthodontic miniscrew-implant in different types of mouthwash: An in-vitro study.
J Orthod Sci. 2022 Jan 28;11:5. doi: 10.4103/jos.jos_158_21. eCollection 2022.
6
Comparison of Cell Viability and Chemical Composition of Six Latest Generation Orthodontic Wires.
Int J Biomater. 2021 Jan 27;2021:8885290. doi: 10.1155/2021/8885290. eCollection 2021.
7
Evaluation of toxicity and response to oxidative stress generated by orthodontic bands in human gingival fibroblasts.
Angle Orthod. 2020 Mar;90(2):285-290. doi: 10.2319/110717-761.1. Epub 2019 Dec 5.

本文引用的文献

2
Behavior of osteoblasts on TI surface with two different coating designed for orthodontic devices.
J Mater Sci Mater Med. 2015 Jan;26(1):5335. doi: 10.1007/s10856-014-5335-9. Epub 2015 Jan 11.
3
Contemporary esthetic nickel-titanium wires: do they deliver the same forces?
Angle Orthod. 2015 Jan;85(1):95-101. doi: 10.2319/092513-701.1.
4
Effect of pH on in vitro biocompatibility of orthodontic miniscrew implants.
Prog Orthod. 2013 Jul 1;14:15. doi: 10.1186/2196-1042-14-15.
5
Effects of intraoral aging on surface properties of coated nickel-titanium archwires.
Angle Orthod. 2014 Jul;84(4):665-72. doi: 10.2319/081213-593.1. Epub 2013 Dec 5.
6
Corrosion resistance of surface modified nickel titanium archwires.
Angle Orthod. 2014 Mar;84(2):358-67. doi: 10.2319/021813-140.1. Epub 2013 Sep 4.
7
Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires.
Am J Orthod Dentofacial Orthop. 2013 Apr;143(4 Suppl):S85-91. doi: 10.1016/j.ajodo.2012.09.009.
8
Effect of nickel chloride on cell proliferation.
Open Dent J. 2012;6:177-81. doi: 10.2174/1874210601206010177. Epub 2012 Nov 16.
9
Cytotoxicity of esthetic, metallic, and nickel-free orthodontic brackets: cellular behavior and viability.
Am J Orthod Dentofacial Orthop. 2012 Jul;142(1):70-4. doi: 10.1016/j.ajodo.2012.02.025.
10
In-vitro assessment of oxidative stress generated by orthodontic archwires.
Am J Orthod Dentofacial Orthop. 2012 May;141(5):583-9. doi: 10.1016/j.ajodo.2011.11.020.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验