Churchman Scott A, Moss John A, Baum Marc M
Auritec Pharmaceuticals, Inc., 2285 E. Foothill Blvd., Pasadena, CA, United States.
Department of Chemistry, Oak Crest Institute of Science, 128-132 W. Chestnut Ave., Monrovia, CA, United States.
J Chromatogr B Analyt Technol Biomed Life Sci. 2016 Apr 1;1017-1018:75-81. doi: 10.1016/j.jchromb.2016.02.033. Epub 2016 Mar 2.
An ion chromatographic method with conductivity detection for the precise and accurate analysis of lithium ions in phosphate-buffered saline, used as a cervicovaginal lavage (CVL) fluid, was developed and validated. The lithium ion dilution factor during the CVL is used to calculate the volume of cervicovaginal fluid (CVF) collected. Initial CVL Li(+) concentrations of 1mM and 10mM were evaluated. The method is robust, practical, and afforded an accurate measurement (5% of the measurement, or better) at 24μL of vaginal fluid simulant collected per mL of CVL fluid, as low as 5μLmL(-1) using 10mM Li(+) with a measurement accuracy of 6.7%. Ion chromatograms of real-world CVL samples collected in vivo from common animal models (sheep and pig-tailed macaque) and a human volunteer demonstrate that the analysis is interference-free. The method is readily transferrable and should enable the accurate measurement of CVF volume collected during CVLs benefitting a broad range of research disciplines, including pharmacokinetic, pharmacodynamic, metabolomic, and microbiome studies.
开发并验证了一种采用电导检测的离子色谱法,用于精确、准确地分析用作宫颈阴道灌洗液(CVL)的磷酸盐缓冲盐水中的锂离子。CVL期间的锂离子稀释因子用于计算收集的宫颈阴道液(CVF)的体积。评估了初始CVL Li(+)浓度为1mM和10mM的情况。该方法稳健、实用,在每毫升CVL液收集24μL阴道液模拟物时能进行准确测量(测量值的5%或更佳),使用10mM Li(+)时低至5μLmL(-1),测量准确度为6.7%。从常见动物模型(绵羊和食蟹猴)以及一名人类志愿者体内收集的实际CVL样品的离子色谱图表明该分析无干扰。该方法易于转移,应能准确测量CVL期间收集的CVF体积,有利于广泛的研究领域,包括药代动力学、药效学、代谢组学和微生物组研究。