Some aneurysms without a definable neck and associated parent vessel pathology are particularly difficult to treat and may require clipping with circumferential wrapping. We report the largest available contemporary series examining the techniques of Gore-Tex clip-wrapping of ruptured and unruptured intracranial aneurysms and patient outcomes.
The presentation, location, and shape of the aneurysm; wrapping technique; outcome at discharge and last follow-up; and any change in the aneurysm at last angiographic follow-up were reviewed retrospectively in 30 patients with Gore-Tex clip-wrapped aneurysms.
Gore-Tex clip-wrapping was used in 8 patients with ruptured aneurysms and 22 patients with unruptured aneurysms. Aneurysms included 23 fusiform, 3 blister, and 4 otherwise complex, multilobed, or giant aneurysms. Of the 30 aneurysms, 63% were in the anterior circulation. The overall mean patient age was 52.5 years (range, 17-80 years). Postoperatively, there were no deaths or worsening of neurologic status and no parent vessel stenoses or strokes. The mean Glasgow Outcome Scale score at last follow-up was 4.7. The mean follow-up time was 42.3 months (median, 37.0 months; range, 3-96 months). There were 105.8 patient follow-up years. Aneurysms recurred in 2 patients with Gore-Tex clip-wrapping. No patients developed rehemorrhage. Overall risk of recurrence was 1.9% annually.
Gore-Tex has excellent material properties for circumferential wrapping of aneurysms and parent arteries. It is inert and does not cause a tissue reaction or granuloma formation. Gore-Tex clip-wrapping can be used safely for microsurgical management of ruptured and unruptured cerebral aneurysms with acceptable recurrence and rehemorrhage rates.
一些没有明确瘤颈且伴有相关供血动脉病变的动脉瘤尤其难以治疗,可能需要采用环形包裹夹闭术。我们报告了目前最大规模的当代系列研究,探讨了使用戈尔特斯(Gore-Tex)材料包裹夹闭破裂和未破裂颅内动脉瘤的技术及患者预后情况。
对30例采用戈尔特斯材料包裹夹闭动脉瘤的患者进行回顾性分析,内容包括动脉瘤的临床表现、位置、形态;包裹技术;出院时及末次随访时的预后情况;以及末次血管造影随访时动脉瘤的任何变化。
8例破裂动脉瘤和22例未破裂动脉瘤采用了戈尔特斯材料包裹夹闭术。动脉瘤类型包括23例梭形、3例水泡状以及4例其他复杂、多叶状或巨大动脉瘤。30例动脉瘤中,63%位于前循环。患者总体平均年龄为52.5岁(范围17 - 80岁)。术后无死亡病例,神经功能状态无恶化,未出现供血动脉狭窄或中风。末次随访时格拉斯哥预后评分平均为4.7分。平均随访时间为42.3个月(中位数37.0个月;范围3 - 96个月)。总随访人年数为105.8。2例采用戈尔特斯材料包裹夹闭的患者动脉瘤复发。无患者发生再出血。总体年复发风险为1.9%。
戈尔特斯材料在动脉瘤和供血动脉的环形包裹方面具有出色的材料特性。它具有惰性,不会引起组织反应或肉芽肿形成。戈尔特斯材料包裹夹闭术可安全用于破裂和未破裂脑动脉瘤的显微手术治疗,复发率和再出血率均可接受。