Onishi Hideyuki, Torii Hidemasa, Watanabe Kazuhiro, Tsubota Kazuo, Negishi Kazuno
Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Jpn J Ophthalmol. 2016 May;60(3):142-9. doi: 10.1007/s10384-016-0432-6. Epub 2016 Mar 9.
To compare the clinical outcomes of 3 marking methods for toric intraocular lens (IOL) implantation in cataract patients.
This study included 48 eyes of 48 cataract patients who underwent cataract surgery with toric IOL implantation. The rotational errors of 3 marking methods-the iris pattern marking method (iris pattern group), the pendulum marking method (pendulum group), and the 3-point marking method (3-point group)-were assessed.
The respective rotational errors were 4.0° ± 3.1° (mean ± SD), 5.3° ± 4.1°, and 7.3° ± 6.0°. The iris pattern group had significantly (P = 0.048) smaller rotational errors than did the 3-point group; no significant difference was found between the iris pattern and pendulum groups. However, the differences in postoperative uncorrected distance visual acuity and astigmatism did not reach significance among the 3 groups.
The refractive and visual results of toric IOL implantation using the 3-point marking method were comparable to the other methods evaluated in this study, although the accuracy of the axis alignment of the toric IOLs was significantly lower than that obtained with the iris pattern method.
比较3种标记方法在白内障患者中植入散光人工晶状体(IOL)的临床效果。
本研究纳入48例接受散光IOL植入白内障手术的白内障患者的48只眼。评估3种标记方法——虹膜图案标记法(虹膜图案组)、钟摆标记法(钟摆组)和三点标记法(三点组)的旋转误差。
各自的旋转误差分别为4.0°±3.1°(平均值±标准差)、5.3°±4.1°和7.3°±6.0°。虹膜图案组的旋转误差明显(P = 0.048)小于三点组;虹膜图案组和钟摆组之间未发现显著差异。然而,3组之间术后未矫正远视力和散光的差异未达到显著水平。
尽管散光IOL轴位对准的准确性明显低于虹膜图案法,但使用三点标记法植入散光IOL的屈光和视觉结果与本研究评估的其他方法相当。