J Cataract Refract Surg. 2011 Feb;37(2):235-40. doi: 10.1016/j.jcrs.2010.08.040.
To evaluate the efficacy and rotational stability of an injectable 1-piece hydrophilic acrylic toric intraocular lens (IOL).
Department of Ophthalmology, Hillingdon Hospital, Uxbridge, Middlesex, United Kingdom.
Cohort study.
This study enrolled consecutive patients who had 2.00 diopters (D) or more of preexisting corneal astigmatism. Patients had phacoemulsification with implantation of a T-flex 623T toric IOL through a 2.8 mm astigmatically neutral incision. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities (logMAR), refraction, keratometry, and the cylinder axis of the toric IOL were measured.
Thirty-three eyes of 25 patients were evaluated. The mean preoperative refractive astigmatism was 3.35 D ± 1.20 (SD) and the mean keratometric astigmatism, 3.98 ± 1.89 D, respectively. Four months postoperatively, the mean UDVA was 0.28 ± 0.23 D logMAR, improving to 0.19 ± 0.23 D logMAR CDVA. The mean refractive astigmatism was 0.95 D ± 0.66 D; vector analysis using the Holladay-Cravy-Koch method showed that the mean reduction in refractive astigmatism was 2.94 ± 0.89 D. The mean difference between the intended and the actual final IOL cylinder axis was 3.44 degrees (range 0 to 12).
The toric IOL reduced visually significant keratometric astigmatism and increased spectacle independence after cataract surgery. There were no cases of significant IOL rotation in the capsular bag 4 months postoperatively.
评估一种可注射的 1 件式亲水性丙烯酸散光型人工晶状体(IOL)的疗效和旋转稳定性。
英国米德尔塞克斯郡尤克斯桥希灵登医院眼科。
队列研究。
本研究纳入了 2.00 屈光度(D)或以上的角膜散光的连续患者。患者通过 2.8mm 散光中性切口行白内障超声乳化术并植入 T-flex 623T 散光 IOL。测量未矫正(UDVA)和矫正(CDVA)距离视力(logMAR)、屈光度、角膜曲率和散光 IOL的圆柱轴。
25 例 33 眼患者接受评估。术前平均屈光性散光为 3.35 ± 1.20(SD),平均角膜散光为 3.98 ± 1.89 D。术后 4 个月,平均 UDVA 为 0.28 ± 0.23 D logMAR,改善至 0.19 ± 0.23 D CDVA。平均屈光性散光为 0.95 ± 0.66 D;使用 Holladay-Cravy-Koch 方法进行矢量分析显示,平均屈光性散光降低 2.94 ± 0.89 D。预期与实际最终 IOL 圆柱轴之间的平均差异为 3.44 度(范围 0 至 12)。
散光 IOL 可降低白内障手术后明显的角膜散光,并提高术后对眼镜的依赖度。术后 4 个月,IOL 在囊袋内无明显旋转。