Suppr超能文献

诱导体积描记术潜力可作为休息和中等体力活动期间通气测量的替代指标。

Inductive plethysmography potential as a surrogate for ventilatory measurements during rest and moderate physical exercise.

机构信息

Laboratório de Fisioterapia Cardiopulmonar, Departamento de Fisioterapia, Universidade Federal de São Carlos (UFSCar), São Carlos, SP, Brazil, Universidade Federal de São Carlos, Universidade Federal de São Carlos, Departamento de Fisioterapia, São Carlos SP , Brazil.

Laboratório de Fisioterapia Cardiovascular, Departamento de Fisioterapia, Universidade Federal de São Carlos (UFSCar), São Carlos, SP, Brazil, Universidade Federal de São Carlos, Universidade Federal de São Carlos, Departamento de Fisioterapia, São Carlos SP , Brazil.

出版信息

Braz J Phys Ther. 2016 Mar 15;20(2):184-8. doi: 10.1590/bjpt-rbf.2014.0147.

Abstract

BACKGROUND

Portable respiratory inductive plethysmography (RIP) systems have been validated for ventilatory assessment during resting conditions and during incremental treadmill exercise. However, in clinical settings and during field-based exercise, intensity is usually constant and submaximal. A demonstration of the ability of RIP to detect respiratory measurements accurately during constant intensity conditions would promote and validate the routine use of portable RIP devices as an alternative to ergospirometry (ES), the current gold standard technique for ventilatory measures.

OBJECTIVE

To investigate the agreement between respiratory variables recorded by a portable RIP device and by ES during rest and constant intensity exercise.

METHOD

Tidal volume (VT), respiratory rate (RR) and minute ventilation (VE) were concurrently acquired by portable RIP and ES in seven healthy male volunteers during standing rest position and constant intensity treadmill exercise.

RESULTS

Significant agreement was found between RIP and ES acquisitions during the standing rest position and constant intensity treadmill exercise for RR and during the standing rest position for VE.

CONCLUSION

Our results suggest that portable RIP devices might represent a suitable alternative to ES during rest and during constant submaximal exercise.

摘要

背景

便携式呼吸感应体积描记(RIP)系统已在静息状态和递增跑步机运动期间的通气评估中得到验证。然而,在临床环境中和基于现场的运动中,强度通常是恒定的且为亚最大强度。RIP 在恒定强度条件下准确检测呼吸测量值的能力的证明将促进和验证便携式 RIP 设备作为运动心肺功能测试(ES)的替代方法的常规使用,后者是目前用于通气测量的金标准技术。

目的

研究在静息和恒强度运动期间,便携式 RIP 设备和 ES 记录的呼吸变量之间的一致性。

方法

在 7 名健康男性志愿者处于站立静息位和恒强度跑步机运动期间,同时通过便携式 RIP 和 ES 采集潮气量(VT)、呼吸频率(RR)和分钟通气量(VE)。

结果

在站立静息位和恒强度跑步机运动期间,RR 在站立静息位时 VE 方面,RIP 和 ES 采集之间存在显著一致性。

结论

我们的结果表明,在静息和恒定亚最大强度运动期间,便携式 RIP 设备可能是 ES 的合适替代方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fd07/4900041/8a036cf229cc/1413-3555-rbfis-20-02-00184-gf01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验