Suppr超能文献

高压氧舱内机械通气的容量监测仪。

Volume monitor for mechanical ventilation in the hyperbaric chamber.

作者信息

Youn B A, Myers R A

机构信息

Department of Hyperbaric Medicine, Geisinger Medical Center, Danville, PA.

出版信息

Crit Care Med. 1989 May;17(5):453-4. doi: 10.1097/00003246-198905000-00015.

Abstract

Treatment of critically ill patients requiring ventilatory support and hemodynamic monitoring in the hyperbaric medicine department is a frequent occurrence. We provide mechanical ventilation principally with the Penlon Oxford ventilator; however, its simple design lacks volume, rate, and disconnect monitors. Therefore, we combined the ventilator with the Ohmeda volume monitor, a pulmonary function monitor for adult and pediatric use that gives reliable, accurate measurements of tidal volume, rate, and minute ventilation. The Ohmeda unit is easily adaptable to the Penlon ventilator, and may also be used to monitor respiratory function in the spontaneously breathing patient. To our knowledge, this is the only battery-driven monitor on the market that provides rate, volume, apnea, and minute ventilation within the same unit. It should be used as an adjunct to the Penlon Oxford ventilator in the hyperbaric chamber.

摘要

在高压氧医学科,对需要通气支持和血流动力学监测的危重症患者进行治疗是常有的事。我们主要使用Penlon Oxford呼吸机进行机械通气;然而,其设计简单,缺少潮气量、呼吸频率和脱机监测功能。因此,我们将该呼吸机与Ohmeda容量监测仪相结合,这是一款供成人和儿童使用的肺功能监测仪,可对潮气量、呼吸频率和分钟通气量进行可靠、准确的测量。Ohmeda装置很容易适配Penlon呼吸机,也可用于监测自主呼吸患者的呼吸功能。据我们所知,这是市场上唯一一款电池驱动的监测仪,可在同一装置内提供呼吸频率、潮气量、呼吸暂停和分钟通气量监测功能。它应作为Penlon Oxford呼吸机在高压氧舱中的辅助设备使用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验