Suppr超能文献

连续和间断递增式跑步机测试在评估最大摄氧量时的速度方面的比较。

Comparison between continuous and discontinuous incremental treadmill test to assess velocity at V̇O2max.

作者信息

Riboli Andrea, Cè Emiliano, Rampichini Susanna, Venturelli Massimo, Alberti Giampietro, Limonta Eloisa, Veicsteinas Arsenio, Esposito Fabio

机构信息

Department of Biomedical Sciences for Health (SCIBIS), University of Milan, Milan, Italy.

Center of Sports Medicine, Don Gnocchi Foundation, Milan, Italy.

出版信息

J Sports Med Phys Fitness. 2017 Sep;57(9):1119-1125. doi: 10.23736/S0022-4707.16.06393-3. Epub 2016 Apr 13.

Abstract

BACKGROUND

The velocity associated with maximum aerobic power (vV̇O2max) is an important physiological parameter, which is utilized to determine relative workloads on the field. The testing modality adopted to evaluate it, though, may cause differences in vV̇O2max assessment and, in turn, in training intensity. The aim of the study was to compare two different testing modalities (continuous incremental ramp and discontinuous square wave (SW) protocols) for vV̇O2max assessment on the treadmill.

METHODS

Seventeen physically active participants performed three maximum incremental tests on a treadmill: two continuous ramp protocols, with different ramp slopes (R1, 1 km/h every minute; and R2, 1 km/h every 2 minutes), and one discontinuous SW protocol, in random order, for maximum oxygen uptake (V̇O2max) and vV̇O2max determination. Cardiorespiratory and metabolic parameters were collected breath-by-breath at rest and during exercise.

RESULTS

vV̇O2max was significantly higher in R1 and R2 compared to SW (20.7±0.5, 18.6±0.4, 16.8±0.6 km/h for R1, R2, and SW, respectively; P<0.001). No significant differences were found among protocols for V̇O2max (56.7±1.1, 57.0±1.2, and 56.6±1.2 mL/min/kg for SW, R1, R2, respectively) as well as for expiratory ventilation, carbon dioxide production, blood lactate concentration, and heart rate.

CONCLUSIONS

In spite of similar V̇O2max values, vV̇O2max was higher during continuous incremental ramp tests compared to SW possibly due to the longer time for cardiorespiratory and metabolic adjustments, suggesting different aerobic and anaerobic metabolism involvement. The differences among protocols should be considered when vV̇O2max is used for training purposes.

摘要

背景

与最大摄氧量相关的速度(vV̇O2max)是一个重要的生理参数,用于确定场上的相对工作量。然而,用于评估它的测试方式可能会导致vV̇O2max评估的差异,进而导致训练强度的差异。本研究的目的是比较两种不同的测试方式(连续递增斜坡和间断方波(SW)方案)在跑步机上评估vV̇O2max。

方法

17名身体活跃的参与者在跑步机上进行了三次最大递增测试:两次连续斜坡方案,具有不同的斜坡坡度(R1,每分钟1公里/小时;R2,每2分钟1公里/小时),以及一次间断SW方案,以随机顺序进行,用于测定最大摄氧量(V̇O2max)和vV̇O2max。在休息和运动期间逐次呼吸收集心肺和代谢参数。

结果

与SW相比,R1和R2中的vV̇O2max显著更高(R1、R2和SW分别为20.7±0.5、18.6±0.4、16.8±0.6公里/小时;P<0.001)。在V̇O2max(SW、R1、R2分别为56.7±1.1、57.0±1.2和56.6±1.2毫升/分钟/千克)以及呼气通气、二氧化碳产生、血乳酸浓度和心率方面,各方案之间未发现显著差异。

结论

尽管V̇O2max值相似,但与SW相比,连续递增斜坡测试期间的vV̇O2max更高,这可能是由于心肺和代谢调整的时间更长,表明有氧和无氧代谢的参与不同。当vV̇O2max用于训练目的时,应考虑各方案之间的差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验