Suppr超能文献

通过两帧相位标记进行EPI奈奎斯特鬼影和几何失真校正

EPI Nyquist ghost and geometric distortion correction by two-frame phase labeling.

作者信息

Xie Victor B, Lyu Mengye, Wu Ed X

机构信息

Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Pokfulam, Hong Kong SAR, China.

Department of Electrical and Electronic Engineering, The University of Hong Kong, Pokfulam, Hong Kong SAR, China.

出版信息

Magn Reson Med. 2017 May;77(5):1749-1761. doi: 10.1002/mrm.26251. Epub 2016 May 2.

Abstract

PURPOSE

To develop a new Nyquist ghost and geometric distortion correction method in echo planar imaging (EPI) using parallel imaging.

METHODS

Two frames of EPI data are acquired with normal and phase-labeled sequence. The phase label is applied by modifying the PE prephase gradient to shift the central echo by one echo spacing. GRAPPA weights are trained from both frames and used to reconstruct images from positive or negative echoes in each frame to remove Nyquist ghost. Geometric distortion is then corrected by the B field map generated from the phase difference between positive and negative echo images. Phantom and in vivo experiments at 7 Tesla (T) and 3T were performed to evaluate the proposed method.

RESULTS

Nyquist ghost was greatly reduced in all images even under oblique imaging and poor eddy current conditions, yielding significant improvements over the existing reference scan and image entropy minimization based methods. Image geometries were fully restored after distortion correction. Phantom results indicated that the signal-to-noise ratio efficiency was largely preserved while fMRI results showed no apparent degradation of temporal resolution.

CONCLUSION

The proposed method provides robust correction of both Nyquist ghost and geometric distortion in EPI, and it is particularly suitable for dynamic EPI applications. Magn Reson Med 77:1749-1761, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

摘要

目的

开发一种利用并行成像在回波平面成像(EPI)中进行新型奈奎斯特鬼影和几何畸变校正的方法。

方法

使用正常序列和相位标记序列采集两帧EPI数据。通过修改相位编码预相位梯度来应用相位标记,使中心回波偏移一个回波间隔。从两帧数据中训练GRAPPA权重,并用于重建每一帧中正向或负向回波的图像,以去除奈奎斯特鬼影。然后通过由正向和负向回波图像之间的相位差生成的B场图来校正几何畸变。在7特斯拉(T)和3T条件下进行了体模和活体实验,以评估所提出的方法。

结果

即使在倾斜成像和涡流条件较差的情况下,所有图像中的奈奎斯特鬼影也大大减少,与现有的参考扫描和基于图像熵最小化的方法相比有显著改进。畸变校正后图像几何形状完全恢复。体模结果表明信噪比效率基本保持,而功能磁共振成像结果显示时间分辨率没有明显下降。

结论

所提出的方法能对EPI中的奈奎斯特鬼影和几何畸变进行可靠校正,特别适用于动态EPI应用。《磁共振医学》77:1749 - 1761, 2017。© 2016国际磁共振医学学会。