Li Jia, Kong Fanlong, Gao Xianda, Shen Yong, Gao Shijun
Department of Orthopaedic Surgery and Key Laboratory of Orthopedic Biomechanics of Hebei Province, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.
Department of Orthopaedic Surgery and Key Laboratory of Orthopedic Biomechanics of Hebei Province, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.
Arthroscopy. 2016 Dec;32(12):2548-2555. doi: 10.1016/j.arthro.2016.04.024. Epub 2016 Jun 7.
To evaluate posterior stability and proprioception after arthroscopic posterior cruciate ligament reconstruction with autograft, hybrid graft, and γ-irradiated allograft.
This prospective, randomized controlled trial (with 5 years' follow-up) included 90 patients who underwent posterior cruciate ligament reconstruction with autograft (gracilis and semitendinosus tendons), hybrid graft (γ-irradiated tibialis anterior tendon allograft and semitendinosus tendon autograft), or γ-irradiated allograft (tibialis anterior tendons). All the γ-irradiated allografts (tibialis anterior tendons) received an irradiation dose of 2.5 Mrad before distribution. Patients in this study had undergone a preoperative magnetic resonance imaging scan and physical examination. Patients were excluded from the study if they had a concomitant injury to other knee ligaments, previous surgery on the injured knee, or articular cartilage lesions greater than Outerbridge grade II. Clinical and proprioceptive evaluation results were collected preoperatively and at 3, 6, 12, 24, 36, and 60 months after surgery.
The autograft, allograft, and hybrid graft groups were followed up for 5.5 ± 0.2 months (range, 5 to 6 years), 5.7 ± 0.3 months (range, 5 to 6 years), and 5.6 ± 0.5 months (range, 5 to 6 years), respectively. No statistically significant differences were found among the 3 groups regarding preoperative demographic factors (P > .05). The differences in physical examination findings and subjective evaluations among the 3 groups were not significant (P > .05). However, a significant difference was detected in instrumented anteroposterior measurements, with more laxity shown in the γ-irradiated allograft group than in the other 2 groups (P = .006).
The differences in proprioceptive and functional outcomes among the 3 groups were not significant. In contrast, a significant difference was detected in instrumented anteroposterior measurements, which showed more laxity in the γ-irradiated allograft group than in the other 2 groups. However, this may not be clinically significant.
Level II, prospective comparative study.
评估自体移植物、混合移植物和γ射线辐照同种异体移植物在关节镜下后交叉韧带重建术后的后向稳定性和本体感觉。
这项前瞻性随机对照试验(随访5年)纳入了90例行后交叉韧带重建术的患者,分别采用自体移植物(股薄肌和半腱肌腱)、混合移植物(γ射线辐照的胫骨前肌腱同种异体移植物和半腱肌腱自体移植物)或γ射线辐照同种异体移植物(胫骨前肌腱)。所有γ射线辐照的同种异体移植物(胫骨前肌腱)在分发前接受2.5兆拉德的辐照剂量。本研究中的患者均接受了术前磁共振成像扫描和体格检查。如果患者合并有其他膝关节韧带损伤、受伤膝关节既往手术史或关节软骨损伤大于Outerbridge II级,则排除在研究之外。在术前以及术后3、6、12、24、36和60个月收集临床和本体感觉评估结果。
自体移植物组、同种异体移植物组和混合移植物组的随访时间分别为5.5±0.2个月(范围5至6年)、5.7±0.3个月(范围5至6年)和5.6±0.5个月(范围5至6年)。三组术前人口统计学因素无统计学显著差异(P>.05)。三组体格检查结果和主观评估的差异不显著(P>.05)。然而,在仪器测量的前后向测量中检测到显著差异,γ射线辐照同种异体移植物组比其他两组表现出更大的松弛度(P=.006)。
三组之间本体感觉和功能结果的差异不显著。相比之下,在仪器测量的前后向测量中检测到显著差异,γ射线辐照同种异体移植物组比其他两组表现出更大的松弛度。然而,这可能在临床上并无显著意义。
II级,前瞻性比较研究。