Nataraj G, Kanade S, Mehta P
Department of Microbiology, Seth Gordhandas Sunderdas Medical College and King Edward Memorial Hospital, Mumbai, India.
Int J Tuberc Lung Dis. 2016 Jul;20(7):890-4. doi: 10.5588/ijtld.15.0849.
Department of microbiology at a tertiary care hospital, Mumbai, India.
To determine 1) the sensitivity and specificity of the Xpert(®) MTB/RIF assay in comparison with microscopy and culture in extra-pulmonary tuberculosis (EPTB), and 2) the number of additional cases of EPTB and rifampicin (RMP) resistance detected using this assay.
The study was conducted from July 2013 to April 2015. All consecutive patients with clinically suspected EPTB referred for microscopic examination to the Department of Microbiology that were sufficient in specimen volume were included in the study.
Of the 728 specimens included in the study, respectively 5.5%, 23.5% and 20.9% were positive on smear, culture and Xpert. Compared to culture, Xpert had a sensitivity of 84.2% (95%CI 81.4-86.6) and specificity of 98.2% (95%CI 90-104). All specimens with high and medium load on assay were positive on culture; 28 (18.4%) specimens were RMP-resistant and 124 (81.6%) were Xpert-susceptible. No additional RMP-resistant cases were detected using Xpert as compared to phenotypic drug susceptibility testing.
The ability of the Xpert assay to rapidly detect a significantly greater number of bacteriologically confirmed EPTB cases, including RMP-resistant cases, makes it an important diagnostic tool in a TB-endemic country.
印度孟买一家三级护理医院的微生物学系。
1)确定Xpert(®)MTB/RIF检测法相对于显微镜检查和培养法在肺外结核病(EPTB)中的敏感性和特异性;2)使用该检测法检测出的EPTB和利福平(RMP)耐药的额外病例数。
该研究于2013年7月至2015年4月进行。所有临床上疑似EPTB且被转至微生物学系进行显微镜检查、标本量充足的连续患者均纳入研究。
在纳入研究的728份标本中,涂片、培养和Xpert检测的阳性率分别为5.5%、23.5%和20.9%。与培养法相比,Xpert检测法的敏感性为84.2%(95%CI 81.4 - 86.6),特异性为98.2%(95%CI 90 - 104)。检测中所有高载量和中载量标本培养均为阳性;28份(18.4%)标本对RMP耐药,124份(81.6%)对Xpert敏感。与表型药物敏感性试验相比,使用Xpert未检测到额外的RMP耐药病例。
Xpert检测法能够快速检测出大量经细菌学确诊的EPTB病例,包括RMP耐药病例,这使其成为结核病流行国家的一种重要诊断工具。