Tikkinen Janne, Wuorimaa Tomi, Siimes Martti A
Diving Medical Centre, Centre for Military Medicine, SLK, PL 5, FIN-02471, Upinniemi, Finland,
Diagnostic-Therapeutic Department, University of Helsinki, Finland.
Diving Hyperb Med. 2016 Jun;46(2):82-6.
Inert gas narcosis (IGN) impairs cognitive performance and some divers are more susceptible to IGN than others. We compared the sensitivity of two reaction time tests to detect changes in performance at pressure and compared these results with critical flicker fusion frequency (CFF) changes at the same ambient pressures.
The study assessed simple reaction time (RT), mean time correct of the discrimination reaction time (MTC) and CFF in 30 professional divers breathing air at 101 kPa and 608 kPa in a hyperbaric chamber.
RT and MTC increased at 608 kPa by 5.1 ± 9.4% (P = 0.04) and 7.3 ± 12.3% (P = 0.01) respectively. RT decreased to pre-compression level after decompression and MTC decreased to a level lower than pre-compression (P < 0.001) values. CFF increased by 2.5 ± 2.8% (P < 0.001) at 608 kPa. CFF decreased to pre-compression level after decompression. An increase in CFF was inversely correlated with a decrease in RT (r = 0.38, P = 0.04) and in MTC (r = 0.43, P = 0.02) at 608 kPa.
Response speeds of the same subjects were impaired in both reaction time tasks at 608 kPa, whereas CFF increased at depth. An association between changes in response times and changes in CFF suggests that divers susceptible to IGN may also be susceptible to the effects of elevated oxygen partial pressure. If this holds true, the future selection of professional divers could be improved by the use of simple cognitive tests.
惰性气体麻醉(IGN)会损害认知能力,并且一些潜水员比其他潜水员更容易受到IGN的影响。我们比较了两种反应时间测试在压力下检测性能变化的敏感性,并将这些结果与相同环境压力下的临界闪烁融合频率(CFF)变化进行了比较。
该研究评估了30名职业潜水员在高压舱内呼吸101 kPa和608 kPa空气时的简单反应时间(RT)、辨别反应时间的平均正确时间(MTC)和CFF。
在608 kPa时,RT和MTC分别增加了5.1±9.4%(P = 0.04)和7.3±12.3%(P = 0.01)。减压后RT降至压缩前水平,MTC降至低于压缩前(P < 0.001)的值。在608 kPa时,CFF增加了2.5±2.8%(P < 0.001)。减压后CFF降至压缩前水平。在608 kPa时,CFF的增加与RT的减少(r = 0.38,P = 0.04)和MTC的减少(r = 0.43,P = 0.02)呈负相关。
在608 kPa时,同一受试者在两项反应时间任务中的反应速度均受损,而CFF在深度增加时升高。反应时间变化与CFF变化之间的关联表明,易受IGN影响的潜水员可能也易受氧分压升高的影响。如果这一情况属实,那么使用简单的认知测试可能会改善未来职业潜水员的选拔。