Suppr超能文献

基于碳基发生器系统的超短寿命铱-191m在评估左心室功能中的临床应用价值。

Clinical usefulness of ultrashort-lived iridium-191m from a carbon-based generator system for the evaluation of the left ventricular function.

作者信息

Franken P R, Dobbeleir A A, Ham H R, Brihaye C, Guillaume M, Knapp F F, Vandevivere J

机构信息

Division of Nuclear Medicine, Middelheim Hospital, Belgium.

出版信息

J Nucl Med. 1989 Jun;30(6):1025-31.

PMID:2738684
Abstract

Ultrashort-lived 191mIr (4.96 sec; 63-74 and 129 keV photons) is potentially advantageous for first-pass radionuclide angiocardiography, offering the opportunity to perform repeat studies with very low absorbed radiation dose to the patient. Left ventricular (LV) first-pass studies were performed in 72 patients with 191mIr from a new bedside 1.3 Ci (48.1 GBq) 191Os/191mIr generator system using an activated carbon support that offers high 191mIr yields (15-18%) and consistent low 191Os breakthrough (2-4 x 10(-4)%/bolus). Using a single crystal digital gamma camera, uncorrected end-diastolic counts in the left ventricular representative cycle ranged from 10 up to 30 k counts. The reproducibility of repeated LV ejection fraction (LVEF) determination at 2-min intervals in 50 patients was r = 0.97, mean diff. = 2.08 +/- 1.55 EF units. Comparison between 191mIr (80-120 mCi; 2,960-4,400 MBq) and 99mTc (20-25 mCi; 750-925 MBq) LV count rates indicates a 3 wk useful shelf life of this new generator system for cardiac studies. Iridium-191m determined LVEF correlated closely with 99mTc determined LVEF in 32 patients (r = 0.96, mean diff. = 1.87 +/- 1.23 EF units). Parametric images for LV wall motion analysis were comparable with both isotopes. We conclude that rapid, repeat, and reproducible high count rate first-pass left ventricular studies can be obtained with 191mIr from this new 191Os/191mIr generator system using a single crystal digital gamma camera.

摘要

超短寿命的191m铱(半衰期4.96秒;发射63 - 74 keV和129 keV光子)对于首次通过放射性核素血管造影术具有潜在优势,可为患者提供以非常低的吸收辐射剂量进行重复检查的机会。使用一种新型床边1.3居里(48.1吉贝可)的191锇/191m铱发生器系统,该系统采用活性炭载体,191m铱产率高(15 - 18%)且191锇的突破量持续低(2 - 4×10⁻⁴%/团注),对72例患者进行了左心室首次通过研究。使用单晶数字伽马相机,左心室代表性心动周期中未校正的舒张末期计数范围为10至30千计数。50例患者每隔2分钟重复测定左心室射血分数(LVEF)的重复性为r = 0.97,平均差值 = 2.08 ± 1.55 EF单位。191m铱(80 - 120毫居里;2960 - 4400兆贝可)与99m锝(20 - 25毫居里;750 - 925兆贝可)左心室计数率的比较表明,这种新型发生器系统用于心脏研究的有效保质期为3周。在32例患者中,191m铱测定的LVEF与99m锝测定的LVEF密切相关(r = 0.96,平均差值 = 1.87 ± 1.23 EF单位)。两种同位素用于左心室壁运动分析的参数图像具有可比性。我们得出结论,使用单晶数字伽马相机,通过这种新型191锇/191m铱发生器系统的191m铱可获得快速、可重复且具有可重复性的高计数率首次通过左心室研究。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验