Dry needling (DN) is reported to decrease pain and improve functional movements yet the mechanisms remain unclear. Changes in muscle tone and other mechanical properties after DN could contribute to these findings but have not been investigated.
Examine EMG and passive mechanical properties of the quadriceps muscle before and after DN.
EMG, MyotonPro and clinical measurements were taken pre and post DN.
Rehabilitation department at Aspetar Sports Medicine Hospital, Qatar.
20 subjects reporting pain and quadriceps muscle tension.
Pain (VAS, measured during a single leg step down), knee flexion range, and passive mechanical properties of the superficial quadriceps were measured using the MyotonPro device.
Pain decreased (p < 0.01) and ROM increased in flexion (p < 0.001). EMG activity (RMS) was decreased at rest in the Vastus Lateralis (VL (p < 0.05, ES = 0.22). All other sEMG parameters were not significantly different (all p > 0.11, ES = 0.13). Passive mechanical properties were not significantly different in rectus femoris (RF) and VL. Decrement and Resistance of the Vastus Medialis (VM) were significantly decreased (p<0.05, ES>0.19).
DN resulted in small reductions in: pain, resting activation (EMG of VL), decrement and resistance (of VM).
干针疗法(DN)据报道可减轻疼痛并改善功能运动,但机制尚不清楚。DN 后肌肉张力和其他机械性能的变化可能导致这些发现,但尚未进行研究。
研究干针治疗前后股四头肌的肌电图(EMG)和被动机械特性。
在干针治疗前后进行 EMG、MyotonPro 和临床测量。
卡塔尔 Aspetar 运动医学医院康复科。
20 名报告疼痛和股四头肌紧张的受试者。
使用 MyotonPro 设备测量疼痛(VAS,在单腿台阶下降过程中测量)、膝关节屈曲范围和股四头肌浅层的被动机械特性。
疼痛减轻(p<0.01),膝关节屈曲度增加(p<0.001)。股外侧肌(VL)的静息状态下的 EMG 活动(RMS)降低(p<0.05,ES=0.22)。其他 sEMG 参数无显著差异(均 p>0.11,ES=0.13)。股直肌(RF)和股外侧肌的被动机械特性无显著差异。股中间肌(VM)的弛豫和阻力明显降低(p<0.05,ES>0.19)。
DN 导致:疼痛、静息激活(VL 的 EMG)、弛豫和阻力(VM)的减少。